2.2.5 VEXT connection (UJA1168AXF-EVB)
An additional 5 V regulator output voltage is provided on the UJA1168AXF-EVB. It is
intended to supply external components and can deliver up to 30 mA. A decoupling
capacitor, C9, is connected between VEXT and GND.
UJA1168AXF
UJA1168AXF-EVB
VEXT (pin 7)
J3-10: outputs 5 V voltage to supply ECU external loads
Table 7. VEXT connection
VEXT can be accessed on J3, on the top of the evaluation board.
aaa-040309
UJA1168AXF
VEXT(p7)
GND(p2)
C9
4.7 µF
VEXT
GND
J3
Figure 6. VEXT supply connections (only relevant for UJA1168AXF-EVB)