3.3 V to 5.0 V translator board connected to FRDM-KL25Z MCU (KITGD3160TREVB)
with micro-USB cable for using FlexGUI software control
•
Quick Start Guide
3.2 Additional hardware
In addition to the kit contents, the following hardware is necessary or beneficial when
working with this kit.
•
Microcontroller for SPI communication
•
Compatible eMPack power module from Semikron
•
DClink capacitor compatible with eMPack power module
•
HV power supply with protection shield and hearing protection
•
Current sensors for monitoring each phase current
•
12 V, 1.0 A DC power supply
•
4-channel oscilloscope with appropriate isolated probes
3.3 Windows PC workstation
This reference design requires a Windows PC workstation. Meeting these minimum
specifications should produce great results when working with this reference design.
•
USB-enabled computer with Windows 8 or Windows 10
3.4 Software
The Flex GUI software must be installed in order to use this kit. All listed software is
available on the information page at
http://www.nxp.com/RDGD31603PSMKEVM
•
Flex GUI software for using with KITGD3160TREVB MCU/translator board
4 Getting to know the hardware
4.1 RDGD31603PSMKEVM features
•
Capability to perform double pulse and short-circuit tests on Phase U using
KITGD3160TREVB and FlexGUI. See schematics for phase U and FlexGUI Pulse tab
(
Figure 32
and
Figure 33
)
•
Evaluation board designed for and populated with GD3160 Gate Drivers and protection
circuitry
•
Capability to connect to eMPack specific modules for full three-phase evaluation and
development (see
Figure 8
for specific module pin placement)
•
Daisy chain SPI communication (three high-side and three low-side gate drivers)
•
Variable fly-back VCC power supply with GND reference and variable VEE supply
•
Easy access power, ground, and signal test points
•
Optional connection for DC bus voltage monitoring