Nvis 5586A
Nvis Technologies Pvt. Ltd.
86
Example
9:
ASCII to HEX conversion.
After changing the ASCII in AL to HEX code, the higher byte is stored in AH and the lower
byte is stored in AL.
Address
Opcode
Mnemonic
Comment
0400
B3 80
MOV
AL, 1A
MOVE 1A IN AL REGISTER
0402
9A 78 F0 00 F0
CALL
F000:F074
CALL SUBROUTINE
0407
B8 88 80
MOV
[450], AH
[450]
31
040B
9A 94 F0 00 F0
MOV
[450], AL
[451]
41
040F
F4
HLT
HALT