Nvis 5586A
Nvis Technologies Pvt. Ltd.
60
2.
Now press the key I and the LCD display is as shown here:
Modify using <Space> and <Backspace >keys as follows:
3.
Press the key F7 and then G. The display will be as follows:
4.
Press the Enter key and then F7.
This indicates the first break-point is at 0402. To proceed further, press G, Enter, and then
F7.
This indicates the second break-point is at 0407. To proceed further, press G, Enter, and then
F7.
This indicates the third break-point is at 0411. One can use any commands including
Examine Register by pressing the key R.
Note:
In above figure observe the command
R
is also displayed this command only appears during
step execution of program or when Breakpoints are applied at some addresses using
I
command.
Display Register:
Command ―R‖ displays the content in the register. This command allows the user to
examine the content of the register in the CPU. Each time during display, 4 registers will be
shown. The following are some of the display and criteria of the register: