Example
14:
HEX to ASCII conversion.
After changing the HEX in AL to ASCII code, ASCII code is stored in AL. Conversion is
valid for 30-39 H & 41-46 H.
Address
Opcode
Mnemonic
Comment
0400
B0 41
MOV
AL, 41
; MOVE 41 IN AL REGISTER
0402
9A 70 F0 00 F0
CALL
F000:F070
CALL SUBROUTINE
0407
B8 88 80
MOV
[450], AL
[450]
0A
040B
F4
HLT
HALT