mstflint Bug Fixes in this Version
For a list of old Bug Fixes, please see
.
Internal
Ref.
Description
2834389
Description: Limited the SET operations on IB devices to registers of up to 240 bytes.
Keywords: mlxreg
Discovered in Version:
4.18.0
Fixed in Release: 4.20.0
2274123
Description: mstfwreset is supported on SmartNic devices on Windows OS only if the device's
name format is "mt*_pciconf*" and not "**:**.*".
Keywords: mstfwreset
Discovered in Version:
4.16.0
Fixed in Release: 4.20.0
2871042
Description: mstfwmanager default query on switches will take pci_cr0 instead of pciconf0,
which is expected to fail in secure-fw switches.
Keywords: mstfwmanager, pci_cr0, pciconf
Discovered in Version:
4.18.0
Fixed in Release: 4.20.0
mstflint Known Issues
The following table provides a list of known issues and limitations of mstflint. For a list of old Known
Issues, please see
file.
Internal Ref.
No.
Issue
2829041
Description: Running mstlink on LID devices when the OpenSM is not enabled, can cause
the machine to hang.
Workaround: To resolve the issue, run the following:
opensm & (Press 'Enter')
mst restart;
mst ib add;
mst status;
Get the correct LID device from "InBand" devices