87
1.
2.
Issue
Cause
Solution
After resetting configuration
using the tool on 5th generation
(Group II) devices, the
configuration's value does not
change
Firmware loads the default
configuration only upon
reboot
Reboot the server
Installation Related Issues
Issue
Cause
Solution
Unable to install the tool package
on ESXi platform and the following
message is printed on the screen:
Got no data from process
Insufficient privileges
Copy the tool's package to /
tmp/vmware and continue
with the installation. If the
issue persists, reboot the ESX
server and try again
Use full file path of the tool's
package
Note: an additional reboot will be
required after completing the
installation
Unable to install kernel-mft in
Linux due to compilation error that
contains the following message:
'error: conflicting types for
'compat_sigset_t''
CONFIG_COMPAT might not be
enabled in the kernel
configuration.
Set the CONFIG_COMPAT to “y” in the
kernel .config file, and rebuild the
kernel.
Firmware Burning Related Issues
Issue
Cause
Solution
The following message is printed
on the screen when performing
firmware update:
An update is needed for the flash
layout.
The operation is not failsafe and
terminating the process is not
allowed.
A flash alignment operation is
required.
Approve the alignment, avoid
process interrupt.