31
1568911, Edition 2019-04, Version 0
6
Mounting Threaded Bolts to the Interface Plate
EN
Figure 15: Mounting the upper insulations to the threaded
bolts
6.3.3 Mounting the upper insulations to the threaded bolts
(See "Figure 15")
The 6 (Single version) or 12 (Duo version) hexagonal nuts M16② must
be mounted to the threaded bolts M16 x 330mm① at an exact distance
to each other.
1. For each threaded bolt M16 x 330mm① screw a hexagonal nut
M16② onto the threaded bolts M16 x 330mm①.
2. Adjust the distance between the hexagonal nuts M16② and the in
-
terface plate
1
:
•
The distance between the hexagonal nuts M16② and the interface
plate
1
must be 150mm.
3. Using a digital spirit level, align the hexagonal nuts M16② in a hori
-
zontal position.
4. Place 1 flat washer with an external diameter of 34mm③.
5. Place 1 plastic insulating disc④ (as illustrated in the Figure) in such
a way that the flat washer with an external diameter of 34mm③
(see arrow in the detailed representation in the Figure) sits in the
plastic insulating disc④.
•
Using an adhesive or elastic tape, attach the plastic insulating disc④
to the threaded bolts M16①.
6. Continue the installation as described in Chapter 7 on Page 32 or
Chapter 8 on Page 36.