28
3.12 Alarm
NO (Number)
alarm input number
PRI (Priority)
the lower number has higher priority (0 ~ 4)
FUN (Function)
Stored function number to be called by alarm.
IN (Input)
NO/NC
– normally open/closed, OFF – ignore
OUT (Output)
OUT1 ~ OUT2
– 5VTTL output, OFF – no output
HLD (Hold)
Alarm will be held for programmed time. (03 to 99 seconds)
LATCH
ON
– Alarm message will remain on the screen even though alarm input is
deactivated.
OFF
– Alarm message will disappear from the screen after programmed
hold time when alarm input is deactivated.
DWELL
means the dwell time during multiple alarms, 03 to 99 seconds.
ALARM:
alarm output is operated during an alarm operation or by the short key of our
keyboard.
1 ~ 5 MIN (minute):
alarm output is operated during this setting time only by the function run
of the dome menu or the short key of our keyboard.
NOTE: This 1 ~ 5 MIN setting is not operated by an alarm.
There are 5 levels of priority. The function can be selected by Preset, Auto scan, Pattern or Tour
and
“0” is the highest priority. Lower priority alarms won’t be serviced until the higher priority
alarm is completed. Equal priority alarms will be serviced repeatedly with the dwell time.
ALARM OUT SETUP
OUT1
: ALARM
OUT2
: 1 MIN
EXIT(ESC TO EXIT)
ALARM SETUP
(CTRL KEY)
NO PRI FUN IN
OUT HLD
1
1
2
1
3
1
001 NO
--- OFF
--- OFF
OUT1 03
OFF
OFF
03
03
4
1 --- OFF OFF 03
LATCH
OFF
OFF
OFF
OFF
DWELL
: 03 SEC
ALARM OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)