OPI-POWER LIFT HF 7000-8000-V1.0-EN
29
6.1 Emergency discharge
There is the option of placing the lift into the lowest
position with a simple operation.
An emergency discharge can only be
done by personnel who are trained to
operate the lift. Follow the conditions
to “Lower”.
Emergency discharge procedure
• People may not stand in the hazardous area
around the lift. Secure the lift area (block off).
• Check whether the latches are engaged.
• Once the latches are engaged, the lift rails must
be lifted with a hoist until the latches can be man-
ually disengaged.
• Securely prevent the latch from locking in using a
suitable aid (e.g. wire) (see photo).
•
Unscrew the screws on the lowering valve (see
photo). The lowering procedure begins immedi-
ately. The lowering speed can be varied by the
rotation position (see photo).
• In case of danger, tighten the emergency dis-
charge screw (if this is possible without endanger
-
ing the operator).
• Always observe the lowering process.
• Lower the lift to the lowest position.
•
If required, firstly inform customer service.
• Only operate the lift again if it is in seamless con-
dition from a safety point of view.
6.2 Moving onto an obstacle
If the lifting rails or lifting arms move onto an ob-
stacle due to operator inattention, the lift stops
in place. To remove the object, raise the lift to a
height where the object can be removed.
For this, push the “Lift” button.
7
Maintenance and care of the lift
i
Before maintenance, do all preparation work
so there is no danger to life or limb or object
damage during maintenance and repair work.
Value is placed on long lifetimes and safety in
the development and production of Nussbaum
products. To guarantee the safety of the oper-
ator, product reliability, low running costs, keep
the warranty and also the long-lifetime of the
product, proper set up and operation is just as
important as regular maintenance and suffi
-
cient care.
Our platforms fulfil or exceed all safety standards of
the countries we supply to. For example, Europe
-
an regulations require a service by qualified experts
every 12 months of work of the platform. To guar-
antee the largest possible availability and function-
al capacity of the lift system, ensure the list of any
cleaning, care and maintenance work is done.
After first commissioning the lift is to be serviced at
regular intervals of a maximum of one year by an
authorised person according to the following plan.
For intensive operation and higher degree of con-
tamination shorten the service interval.
The complete function of the lift is to be observed
during daily use. Customer service must be in-
formed of any malfunctions.
Содержание POWER LIFT HF 7000
Страница 2: ...2 OPI POWER LIFT HF 7000 8000 V1 0 EN...
Страница 4: ......
Страница 20: ...20 OPI POWER LIFT HF 7000 8000 V1 0 EN...
Страница 21: ...OPI POWER LIFT HF 7000 8000 V1 0 EN 21...
Страница 22: ...22 OPI POWER LIFT HF 7000 8000 V1 0 EN...
Страница 23: ...OPI POWER LIFT HF 7000 8000 V1 0 EN 23...
Страница 54: ......
Страница 66: ...66 OPI POWER LIFT HF 7000 8000 V1 0 EN SPX 280 Unit USA...
Страница 67: ...OPI POWER LIFT HF 7000 8000 V1 0 EN 67 SPX Unit USA...
Страница 68: ...68 OPI POWER LIFT HF 7000 8000 V1 0 EN Cross beam 240SLK05840_1 07 09 2018...
Страница 70: ...70 OPI POWER LIFT HF 7000 8000 V1 0 EN Cylinder K HF7000 HF8000 240SLK02501_2...
Страница 71: ...OPI POWER LIFT HF 7000 8000 V1 0 EN 71 Cylinder F HF7000 HF8000 240SLK02602_2...