The devireg™ 535 allows you to program your heating system by using pre-set program modes. Follow the steps 
below to ensure the most desireable outcome to suit your heating requirements. The first step is to configure the 
thermostat:

•  If your devireg™ 535 has not already been configured by an electrician or installer, go to the section “Configuring the 

Thermostat”. Otherwise, skip this step.

•  After your devireg™ 535 has been configured: There are 4 program modes to choose from. Depending on your requirements, 

go to either the section “Manual Mode” or “Program Mode” and follow the steps provided to set up your thermostat.

Configuring the Thermostat

If your thermostat has already been configured by your installer or electrician, there is no need to configure  
the thermostat.

1

Remove  

front cover

To configure or re-configure your thermostat, you will need to remove the front cover. Depending on the type of cover, 
the method of removal is slightly different. Refer to the images above for guidance.
Snap-lock Devireg

 535 Front Cover:

Insert a paper clip  into the slot (as shown in the diagram above) to snap-release the cover. Gently squeeze both sides of 
the cover whilst removing it. Press the top circular button located on the right hand side of the thermostat with a pencil.
Original Devireg

 535 Front Cover (if no slot on the bottom of the cover):

With a small screwdriver, gently press the release tabs on both sides of the thermostat (third groove from the bottom), 
then remove the cover. Press the top circular button located on the right hand side of the thermostat with a pencil.

2

Select  

sensor mode 

If your under floor heating is in a bathroom or wet area, we recommend you select the floor sensor mode  . If it is in a dry 
area like a bedroom or living room, we recommend floor and room sensor mode    . To change the selection press the 
Select (•) button and then use the arrows (



) until the correct symbols appear. Then press the Select (•) button to save. 

Move on to the next screen by using the right hand arrow (

). If you have chosen room sensor mode, go to Step 5.

3

Select  

maximum 

floor 

temperature 

The maximum floor temperature setting should now be displayed on the screen. To change the setting, press the 
Select (•) button. Set the temperature by using the arrows (



) and then press the Select (•) button to select. 

Depending on your floor structure and floor covering, we recommend the following:

Floor Construction

Tiles

Timber

Carpet

Timber base

32°C

27°C

30°C

Concrete or F/C base

45°C

27°C

40°C

Now move to the next screen by pressing the right hand arrow (

). If you have chosen floor and room sensor mode, 

go to Step 5.

4

Choose the 

scale

We recommend using “°C” for floor and room sensing or room sensing only, or 1-6 for floor sensing only. To change 
the current setting, press the Select (•) button and change using the arrows (



), then press Select (•) to save.

5

Save your 

selection

Press the top circular button with a pencil to go back to the original screen. Replace the front cover.

Time Periods (“Morning”, 

“Day”, “Evening” & “Night”)

Weekdays

Settings

Room 

Sensor

Floor 

Sensor

Actual 

Temperature 

is displayed

Childproof

Frost 

Protection

Maximum/ 

Minimum

Heat Indicator:
Red: Heating
Green: At temperature

Note: This is the maximum 
temperature, not your preferred 
operating temperature.