27
GB
3 – PRE-OPERATION CHECK
NOTE:
PRE-OPERATION CHECKS SHOULD BE MADE EACH TIME
THE GENERATOR IS USED.
1) CHECK ENGINE FUEL (PIC. 5)
• Check fuel level at fuel level gauge.
• If fuel level is low, refill with unleaded automotive gasoline.
• Be sure to use the fuel filter screen on the fuel filter neck.
• Recommended fuel: Unleaded gasoline.
WARNING:
• Do not refill tank while engine is running or hot.
• Close fuel cock before refueling with fuel.
• Be careful not to admit dust, dirt, water or other foreign
objects into fuel.
• Wipe off spilt fuel thoroughly before starting engine.
• “F” full, “E” empty.
2) CHECK ENGINE OIL (PIC. 6)
Before checking or refilling oil, be sure the generator is put on a
stable and level surface with engine stopped.
• Remove oil filler cap and check the engine oil level.
• If oil level is below the lower level line, refill with suitable oil
to upper level line. Do not screw in the oil filler cap when
checking oil level.
• Change oil if contaminated.
• Recommended engine oil:
API Service «SE» or «SF», if not available, «SD».
3) GROUND (EARTH)
Make sure to ground (earth) the generator.
4 – OPERATION
NOTE:
THE GENERATOR HAS BEEN SHIPPED WITHOUT ENGINE
OIL. FILL WITH OIL OR IT WILL NOT START.
1) STARTING THE ENGINE
NOTE:
• Before starting the engine, do not connect the electric
equipment(s).
• Turn the AC switch to «OFF». (PIC. 7)
1. Turn the fuel cock lever to «ON». (PIC. 8)
2. Turn the engine switch to «ON». (PIC. 9)
3. Turn the choke lever to the (closed) position. Not necessary
if the engine is warm. (PIC. 10)
4. Pull the starter handle slowly until resistance is felt. This is
the «Compression» point. Return the handle to its original
position and pull swiftly. Do not fully pull out the rope. After
starting, allow the starter handle to return to its original
position while still holding the handle. (PIC. 11)
5. Warm up the engine.
6. Turn the choke lever back to the operating position. (PIC. 12)
7. Warm up the engine without a load for a few minutes.
2) USING ELECTRIC POWER
1 - AC APPLICATION (SINGLE VOLTAGE TYPE)
(a) Check the pilot lamp or the voltmeter for proper voltage.
(b) Turn off the switch(es) of the electrical equipment(s)
before connecting to the generator.
(c) Insert the plug(s) of the electrical equipment(s) into the
receptacle.
(d) Turn the AC switch to the «ON» position and turn on the
electric equipment. (PIC. 13)
CAUTION:
• Be sure the total load is within generator rated output.
• Be sure the socket load current is within socket rated
current.
• To take out power from TWIST LOCK receptacle, insert the
plug into receptacle and turn clockwise to lock it.
2 - AC APPLICATION (DUAL VOLTAGE TYPE) (FIG. 3/B)
(a) Select the voltage using the AC OUTPUT SELECT
SWITCH in accordance with the electrical appliance.
(b) Operate in the same way as step (a) through step (d) of
single voltage type.
NOTE:
Voltmeter always indicates the lower voltage whichever the
AC OUTPUT SELECT SWITCH is set.
3 - DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a) Charging instruction for battery
• Disconnect the leads of the battery.
• Make the battery fluid filler cap loose fully.
• Fill distilled water to the upper limit, if the battery fluid is low
level.
• Measure the specific gravity for the battery fluid by using the
Содержание NPEGG2400
Страница 4: ...11 14 15 16 17 ...
Страница 5: ...12 18 19 20 21 ...