26
Stores Values
& initiates
Differential
1-40°F
Boiler Setpoint for
DHW (80-200°F)
Boiler Setpoint for
Heating (80-200°F)
Sets Outdoor Reset
Curve Slope (70°F-HI)
Sets Starting Gas Input
Value (60-100)
Sets Highest Gas Input
Value (100-240)
Sets Lowest Gas Input
Value (40*-100)
Indirect Water Heater
Error Code (On/Off)
RUN
LO
HI
DIF
RES
SFS
HFS
LFS
ER5
Setting Sentry 2100T Operation
The Trinity boiler employs a pneumatic modulation system. This modulation system increases or decreases the
velocity of the blower, to meet the demand for heating. The gas valve, senses this change, in blower pressure,
and introduces the required amount of gas, to ensure correct combustion. The term “Set Point” is used to indicate
the desired temperature that the Trinity will try and maintain, by increasing or decreasing the input.
Note:
1-
For Combi units the Heating Circ. (C1) is powered for both heating and domestic hot water.
2-
For Combi units the Aux Circ. (Ap) powers the 3-way diverter valve. (Located in the boiler)
3-
For Combi units the boiler will run in domestic mode immediately following a call for heat or domestic, until a boiler temperature of
160
o
F in reached.
4-
For Combi units the burner turns on when the water temperature is less then 190
°
F on the initial call, afterwards it turns back on when
water temperature is less then LO set point.
Setting Sentry 2100 control
Programming is accomplished by a series of three push buttons located on the bottom side of the
control. (
Function,
↑
and
↓
). To enter the programming mode, press the function key once. To scroll
through the various menu options depress
↑
until the menu is displayed. To alter the value press
Function
once, and the current value will be displayed, then use
↑
for up, and
↓
for down, until the
desired value is obtained. To enter the selected value press
Function
, which will return to the menu.
When all desired values are selected, scroll to the RUN menu, and press Function, which exits the
Programming Mode and initiates normal operation. A safety feature has been added to ensure that if the
control is left in the Program Mode, the unit will turn off if left in program mode longer than 30 seconds
without receiving an input. Press
Function
once to continue programming or to start boiler operation.
MENU
To start the control operation, you must return to RUN on the menu, and press Function. Normal operation will
begin. (*Note: LFS must not be set below 48 on Ti150’s.)
T-C & A-C Open
T-C Closed & A-C open
T-C Closed & A-C Close
T-C Open & A-C Closed
Condition
Standby
Note 3
Heating Only
Domestic Only
Domestic Only
Set Point
- HI
Calc.
L0
L0
Burner On
- HI
Calc
– DIF
(LO-10)
Note 4
(LO-10)
Note 4
Burner Off
- HI
Calc
+ 10
200
°
F 200
°
F
Heat Circ. (C1)
Off On
Off
Note 1
Off
Note 1
Aux. Circ. (Ap)
Off Off
On
Note 2
On
Note 2
T-C & A-C Open
T-C Closed & A-C open
T-C Closed & A-C Close
T-C Open & A-C Closed
Condition
Standby
Note 3
Heating Only
Domestic Only
Domestic Only
Set Point
- HI
L0
L0
Burner On
-
HI – DIF
(LO-10)
Note 4
(LO-10)
Note 4
Burner Off
- HI
+
10
200
°
F 200
°
F
Heat Circ.
Off On
Off
Note 1
Off
Note 1
Aux. Circ.
Off Off
On
Note 2
On
Note 2