NTI RACKMUX-V17-N-8USBHD-IP RACKMOUNT DRAWER WITH USB KVM SWITCH AND KVM ON IP
40
RS232 CONTROL
RS232 enables the UNIMUX to be remotely controlled via RS232. To control the UNIMUX via RS232 the user has three options:
write a program that runs on a PC using the Command Protocol (page 42)
use the SerTest or RMTEST programs (pages 43 and 45) installed with the Switch Control Program.
Remote Connection
The RS232 Interface is designed to meet the RS232C standard and can be controlled from any CPU or other controller with an
RS232 communications port. The pin-out for the RJ45 connector on the unit is as follows:
RS232 (RJ45) CONNECTOR
PIN
SIGNAL
FUNCTION
1 -
No
connection
2 -
No
connection
3
RX+
Receive data (TXD at host)
4 GND Ground
5 -
No
connection
6
TX+
Transmit data (RXD at host)
7 -
No
connection
8 -
No
connection
NOTE: Security must be disabled or user access granted on the port(s) to be selected by RS232 control.
A 5 foot patch cable and two adapters, RJ45-to-DB9 and RJ45-to-DB25, have been provided for connection to most CPUs (see
page
Error! Bookmark not defined.
). To daisy chain multiple units, connect a Matrix-Y-1 cable (sold separately) between the
CPU and the first switch, and between each switch (as shown in Figure 51).
Baud Rate
The baud rate can be changed using the OSD menu (page 40) or from the RS232 commands (page 42) . The baud rate can be
set to 115000, 57600, 38400, 19200, 9600, 4800, 2400, or 1200. A data protocol of 8 data bits, no parity, and 1 stop bit is used
for communications.
Unit Address and Loop Back
To allow multiple units to be controlled from a single host port, the RS232 control interface is designed to allow "daisy chaining" up
to 15 units using an NTI Matrix-Y-1 cable. Connect the Matrix-Y-1 cable between the RJ45-to-DB9 serial adapter and the CPU as
shown in Figure 51. By setting the appropriate unit address (page 40), each unit can be given a unique address (1-15). Then the
unit will only respond to commands on the bus if its address is embedded in the command.