20
OY NORDIC SPA LTD | Tehdaskatu 7, 24100 Salo | www.novitek.fi
EN
The error messages are shown at the left lower side. The table below shows the most common error
codes, their meanings and the required measures. Always take the required measures and contact your
distributor or service agent if necessary.
ERROR CODES
CODE
MEANING
REQUIRED MEASURE
DARK SCREEN
The pool is not receiving power.
Turn on power to the pool / check the
connection.
Possible freezing condition
The pool may have frozen
The pumps will turn on automatically,
regardless of the pool’s mode. Contact your
service agent.
Water is too hot
OVERTEMPERATURE – One of the
temperature sensors has detected a
temperature of 43.3 °C or higher.
DO NOT ENTER THE WATER! The pool will
turn off and turn on again once the water
temperature has decreased to 41.7 °C.
Remove the pool cover to cool the water.
The water flow is low
Notable difference in temperatures
measured by sensors A and B. Indicates a
problem with the water flow.
Check that there is enough water, fill if
necessary. Clean the filter and check that
the pumps work. If the problem continues,
contact your service agent.
The water flow has failed
Continuous problems with the water
flow. The heater will turn off if this code
appears five times in a day.
Check that the filter is clean. Turn the
heater on again by pressing any icon.
If the problem continues, contact your
service agent.
The heater may be dry
The water flow in the heater is low, or
there is air in the heater.
Turn the pool off for 15 minutes. Check that
there is enough water and fill if necessary.
If necessary, remove air according to the
instructions for clearing an airlock. Return
the pool to the normal mode by pressing
any icon. If the problem continues, contact
your service agent.
The heater is dry
Not enough water in the heater. The pool
will turn itself off.
Check that there is enough water, fill if
necessary. Clean the filter and check that
the pumps work. If the problem continues,
contact your service agent.
The heater is too hot
OVERTEMPERATURE – One of the
temperature sensors has detected a
temperature of 47.8 °C or higher.
DO NOT ENTER THE WATER! Remove
the pool cover to allow the water to cool.
After the water has cooled down, reset the
system by pressing any icon.
Sensors are out of sync
Temperature sensors out of balance.
The phenomenon may be temporary. If the
problem continues, contact your service
agent.
Sensors are out of sync -- Call for service--
The temperature sensors have been out of
balance for at least an hour.
Contact your service agent.
Sensor A fault, Sensor B fault
Temperature sensor A or B does not work.
The pool has turned off.
May occur momentarily when the
temperature rises too high. The message
will disappear once the temperature
decreases. If the problem continues,
contact your service agent.
A pump may be stuck on
The pump will not turn off.
DO NOT ENTER THE WATER! The water
may have overheated. Turn off power to
the pool and contact your service agent.
SELECT BASIC