03/10 Rev. 5.04-01
USER MANUAL
Mounting & Setting
LA-BO
13
[Fig. 15]
Adjusting the bars in the vacuum grid by matching the outside section of the
sliding bars with the label surface.
Adjusting the air nozzles in the vacuum grid
To achieve optimal labelling apply accuracy it is important to adjust the blow-
off air flow in the center of the label under the vacuum grid. Therefore the air
nozzles of the LA-BO can be fine adjusted in the X (width) and Y (length)
direction in reference to the label area.
To adjust the air nozzles in X-direction (width of label):
[Fig. 16]
Adjusting the air nozzles across feeding direction.
«
Turn the black lower-right knob (fig.16, A) clockwise or counter clockwise
until the sliding bars / nozzles are centered over the width of the label.
¯
This setting becomes more critical for smaller label sizes. If the non-closed
nozzles are not centered over the width of the label, the label will move side-
ways during the blow-on action.
To adjust the air nozzles in Y-direction (length of label):
A