03/10 Rev. 5.04-01
USER MANUAL
Mounting & Setting
LA-BO
9
Firmware 1.34
(Standard signal
interface)
Firmware 1.34
(Applicator
interface)
¯
The
SIGNAL INTERFACE > AI BOARD SIGNAL
menu appears, if the optional applica-
tor interface is installed
and
if
SIGNAL INTERFACE > Interface mode
=
„Applic. signals“.
Menu
Parameter
Value
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of
label sensor to disp. edge, label must be
entirely dispensed)
SIGNAL INTERFACE Interface mode
„Applic. signals“
SIGNAL INTERFACE
> APPLIC. SIGNALS
Applicator type
LA-BO
Apply mode
„After start sig.“
(preferred setting for maximum output
capacity)
Blow on time
60 ms
[Tab. 4]
The parameter settings required for operating the LA-BO applicator on an
ALS 20x/256 (Labeller firmware version: 1.34).
Menu
Parameter
Value
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of
label sensor to disp. edge, label must be
entirely dispensed)
SIGNAL INTERFACE Interface mode
„Applic. signals“
SIGNAL INTERFACE
> AI BOARD SIGNAL
Applicator type
LA-BO
Apply mode
„After start sig.“
(preferred setting for maximum output
capacity)
Blow on time
60 ms
[Tab. 5]
The parameter settings required for operating the LA-BO applicator on an
ALS 20x/256 (Labeller firmware version: 1.34).