03/10 Rev. 5.04-01
USER MANUAL
Mounting & Setting
LA-BO
12
[Fig. 14]
Adjusting the bars in the vacuum grid so air nozzles outside the label surface are
closed off.
3. Carefully adjust the bars to the label size by moving the knobs just against
the label edge, without touching the edge of the label. Bars outside the width
of the label should be fully moved inwards the vacuum grid so all the air noz-
zles above this bar are closed.
4. Proceed some dispensing tests and check if the knobs on the bars are not
touching or holding the edge of the dispensed label.
¯
In most applications with a blow-on applicator, it will be difficult to visually ve-
rify the position of the sliding bars from the bottom side of the vacuum grid.
Therefore, the bars can also be adjusted by matching the section of the bars
outside the vacuum grid to the label surface, as shown on fig.15.