Technical Specifications

 

13

.

1

  

Main specifications of the microscope XSZ-107T

 

Optical System 

160mm path length 

Viewing head 

Siedentopf Binocular Head, inclined at 30° Interpupillary distance of  
55 – 75mm 

Eyepiece 

Wide Field Eyepiece 
WF 10x / 18 
Magnification 10x 
Focal length 25mm 
Field of View 18mm 

Nosepiece 

Quadruple nosepiece  

Focusing 

Coaxial Coarse and Fine Focus adjustment, moving range 20mm, Fine Focus 
Division 0.002mm  

Condenser 

ABBE condenser, NA = 1.25 with iris diaphragm 

Stage 

Double layer mechanical stage 140mm x 140mm. 
 Moving range of 75mm x 50mm 

Illumination 

3.6V 1w Ultra-Bright 350mA LED illumination 

Power Supply 

AC Input  200V or 110V 
DC power output 5.5V 
Battery assistance for power outages 3.6V 3800mAh (8 Hours operation) 

 
 

13.2

 

        Main specifications of the epi-florescence attachment YX-2 

 

 

 

Epi-Fluorescent 
Illumination 

Fluorescent Filter Specifications  
B Exciting Light Filter System 
G Exciting Light Filter System 

Illumination 

3w Ultra Bright CREE-XML LED Diode 

Protection Barrier 

Barrier to Resist the Ultraviolet Light 

Power Supply 

Power supplier AC Input  220V/110V 
(Interchangeable) 3.6v 1000mA constant current DC output 
Power supplier AC Input  220V/110V 
(Interchangeable)  3.6v  1000mA  constant  current  DC  output  with  battery 
back-up 10000 mAh 

Objective 

160mm Fluorescence Free Objective  10X 

160mm Fluorescence Free Objective  20X 

160mm Fluorescence Free Objective  40X 
160mm Fluorescence Free Objective  100X OIL 

Immersion Oil 

Fluorescence Free Oil 

Vertical Illumination 

● Achromatic Optics System 
● Filtering System 

● Observation  Methods 

 

Fluorescence 

 

Transmitted Light (Brightfield)

 

Lamp Housing 

● Aluminium Lamp Housing 
● CREE XM-L 3w LED Illuminator 

Содержание XSZ-107T

Страница 1: ...e YX 2 attachment USER AND OPERATIONAL MANUAL This manual is for the biological microscope XSZ 107T To ensure the safety and optimum performance of this unit please ensure a thorough familiarization w...

Страница 2: ...ram 10 11 9 Adjustment and Operation for brightfield microscopy 12 9 1 Brightness Adjustment 12 10 Focusing on the specimen 13 10 1 Focus on the specimen 13 10 2 Condenser adjustment 13 10 4 Adjusting...

Страница 3: ...ropping to the ground and being damaged The epi fluorescent attachment is a precision instrument b Please ensure that the entire unit is kept out of direct sunlight high temperatures humid or dusty en...

Страница 4: ...r the units as the lenses will get damaged and shall not be replaced under warranty 3 4 If under certain circumstances certain contaminants end up on the lenses i e fingerprints oil smudges one can cl...

Страница 5: ...5 P a g e 4 Components of the microscope...

Страница 6: ...e completed installation of the components The corresponding figures show the assembly steps Before installation ensure the unit is clean as well as every component do not store unpacked units in a ro...

Страница 7: ...op of the microscope body and tighten the holding screw firmly to hold the unit in place 6 2 Installing the binocular head Insert the binocular viewing head into the epi florescence unit and then moun...

Страница 8: ...into the nosepiece from the left or the right side and then revolve the nosepiece clockwise and place one objective per open socket until all the objectives are installed Clean the objectives regularl...

Страница 9: ...its full charge capacity the red light will extinguish and a green light will appear Once in use if one disconnects from the main AC power the internal battery will hold enough current to illuminate...

Страница 10: ...10 P a g e 8 Adjustment Set Diagram...

Страница 11: ...11 P a g e...

Страница 12: ...achment is set to the 0 setting or in the middle setting 9 1 4 Place the specimen slide on the stage in the centre and use the stage swing arm to secure the slide in place 9 1 5 Turn the vertical and...

Страница 13: ...n objective The condenser and objective are coaxial The condenser has been adjusted and pre set before leaving the factory and the maximum height has been pre set so the end user has no need to adjust...

Страница 14: ...nt collar Turn the tension adjustment collar with your fingers When the collar is turned in the direction of the arrow in the figure displayed tension of the coarse adjustment knob increases Turning t...

Страница 15: ...ast of fluorescent images So it is effective to use the shutter frequently to avoid illuminating the specimen for a longer period than required 11 1 6 2 Colour fading of the specimen can also be delay...

Страница 16: ...Hours operation 13 2 Main specifications of the epi florescence attachment YX 2 Epi Fluorescent Illumination Fluorescent Filter Specifications B Exciting Light Filter System G Exciting Light Filter Sy...

Страница 17: ...e nominal voltage Pollution Degree 2 in accordance with IEC 664 Installation Over voltage Category in accordance with IEC 664 12 1 Fluorescent Filter Combinations excitation applications U Auto fluore...

Отзывы: