Application 

The  XSZ-107  series  microscope  is  a  multi-purpose  bio-microscope  that  has  been  specifically  designed  for 

clinical and chemical examination. The application and use of this series of microscopes is very diverse and 

extends  to  professional  research,  teaching  demonstration,  use  in  medical  and  health  establishments, 

laboratories,  technology,  research  and  tertiary  education  facility.  Its  accessories  make  the  instrument 

capable  of  accomplishing  a  very  diverse  and  wide  range  of  practical  use.  The  XSZ-107  can  be  adapted  in 

many ways including phase contrast, florescence, photography, camera depiction, television and computer 

based  image  processing.  The  XSZ-107  can  also  be  used  for  routine  work  in  the  fields  of  biology, 

bacteriology, histology, cytology, haematology and pharmacology easily (to name a few). 

The microscope unit is used in conjunction with the epi-fluorescent attachment which has been designed 

for  use  with  and  including  our  biological  microscopes  such  as  the  Novel  N-400M,  Novel  N320M  and  the 

Novel XSZ-107CCD.  

2.

 

Safety Note

 

a.

 

Carefully open the box, avoid the accessories dropping to the ground and being damaged. 
The epi-fluorescent attachment is a precision instrument. 

b.

 

Please ensure that the entire unit is kept out of direct sunlight, high temperatures, humid or 
dusty environments.  

c.

 

Make certain that the power cords are installed correctly and that all other components are 
connected firmly. 

d.

 

Do not open any of the lamp housings while they are turned on or for at least 10 minutes 
after  they  have  been  turned  off.  These  parts  are  extremely  hot  and  can  cause  burns  if 
touched. 

e.

 

Always be sure to ground (earth) the equipment. 

f.

 

Verify  that the  voltage  and  the frequency  of  the  AC  mains  outlet  match the  setting  of the 
voltage switch and the frequency switch on the rear of the power supply units. 

g.

 

Always  use  the  power  cord  provided  by  NOVEL  and  make  sure  that  the  main  switch  is 
moved to “O” (OFF) before connecting the power cord plug to the wall outlet. 

h.

 

To prevent any hazard, always turn the main switch on the power supply unit to “O” (OFF), 
unplug the power cord plug from the mains outlet before replacing any bulb or the fuse, and 
wait for at least 10 minutes before replacing the bulb. 

i.

 

To prevent obstruction of the air flow, it is important to make sure to leave enough space 
around  and  above  the  lamp  housing  of  the  microscope  as  well  as  epi-florescence 
attachment.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание XSZ-107T

Страница 1: ...e YX 2 attachment USER AND OPERATIONAL MANUAL This manual is for the biological microscope XSZ 107T To ensure the safety and optimum performance of this unit please ensure a thorough familiarization w...

Страница 2: ...ram 10 11 9 Adjustment and Operation for brightfield microscopy 12 9 1 Brightness Adjustment 12 10 Focusing on the specimen 13 10 1 Focus on the specimen 13 10 2 Condenser adjustment 13 10 4 Adjusting...

Страница 3: ...ropping to the ground and being damaged The epi fluorescent attachment is a precision instrument b Please ensure that the entire unit is kept out of direct sunlight high temperatures humid or dusty en...

Страница 4: ...r the units as the lenses will get damaged and shall not be replaced under warranty 3 4 If under certain circumstances certain contaminants end up on the lenses i e fingerprints oil smudges one can cl...

Страница 5: ...5 P a g e 4 Components of the microscope...

Страница 6: ...e completed installation of the components The corresponding figures show the assembly steps Before installation ensure the unit is clean as well as every component do not store unpacked units in a ro...

Страница 7: ...op of the microscope body and tighten the holding screw firmly to hold the unit in place 6 2 Installing the binocular head Insert the binocular viewing head into the epi florescence unit and then moun...

Страница 8: ...into the nosepiece from the left or the right side and then revolve the nosepiece clockwise and place one objective per open socket until all the objectives are installed Clean the objectives regularl...

Страница 9: ...its full charge capacity the red light will extinguish and a green light will appear Once in use if one disconnects from the main AC power the internal battery will hold enough current to illuminate...

Страница 10: ...10 P a g e 8 Adjustment Set Diagram...

Страница 11: ...11 P a g e...

Страница 12: ...achment is set to the 0 setting or in the middle setting 9 1 4 Place the specimen slide on the stage in the centre and use the stage swing arm to secure the slide in place 9 1 5 Turn the vertical and...

Страница 13: ...n objective The condenser and objective are coaxial The condenser has been adjusted and pre set before leaving the factory and the maximum height has been pre set so the end user has no need to adjust...

Страница 14: ...nt collar Turn the tension adjustment collar with your fingers When the collar is turned in the direction of the arrow in the figure displayed tension of the coarse adjustment knob increases Turning t...

Страница 15: ...ast of fluorescent images So it is effective to use the shutter frequently to avoid illuminating the specimen for a longer period than required 11 1 6 2 Colour fading of the specimen can also be delay...

Страница 16: ...Hours operation 13 2 Main specifications of the epi florescence attachment YX 2 Epi Fluorescent Illumination Fluorescent Filter Specifications B Exciting Light Filter System G Exciting Light Filter Sy...

Страница 17: ...e nominal voltage Pollution Degree 2 in accordance with IEC 664 Installation Over voltage Category in accordance with IEC 664 12 1 Fluorescent Filter Combinations excitation applications U Auto fluore...

Отзывы: