Chapter 3 SMART7 Operation
SMART7 Installation and Operation User Manual v6
41
log com2 rtcm1012 ontime 1
log com2 rtcm1006 ontime 10
log com2 rtcm1033 ontime 10
log com2 rtcm1019 ontime 120
log com2 rtcm1020 ontime 120
saveconfig
(optional)
NOVATELX
serialconfig com2 19200 N 8 1 N on
interfacemode com2 none novatelx off
fix position lat lon hgt
(enter your own lat, lon, hgt)
log com2 novatelxobs ontime 1
saveconfig
(optional)
For more information, refer to the
FIX
command,
INTERFACEMODE
command,
SAVECONFIG
com-
mand and
SERIALCONFIG
command in the
Agriculture Commands and Logs Reference Manual
.
3.3.3 Rover Station Configuration
At the rover station, enter the following commands:
serialconfig [port] baud [parity[databits[stopbits[handshaking[break]]]]]
interfacemode port rx_type tx_type [responses]
saveconfig
(optional)
The following sections are examples of rover configurations, if COM2 was connected to the correction source.
RTK Automated Correction Detection
serialconfig com2 19200 N 8 1 N on
interfacemode com2 auto none off
saveconfig
(optional)
RTCM V3
serialconfig com2 19200 N 8 1 N on
interfacemode com2 rtcmv3 none off
saveconfig
(optional)
RTCM V3 with GLONASS
serialconfig com2 19200 N 8 1 N on
interfacemode com2 rtcmv3 none off
saveconfig
(optional)
NOVATELX