![Novatel SMART7 Скачать руководство пользователя страница 124](http://html.mh-extra.com/html/novatel/smart7/smart7_installation-and-operation-user-manual_1711399124.webp)
Chapter 11 NovAtel Firmware and Software
SMART7 Installation and Operation User Manual v6
124
The receiver stops tracking GNSS satellites during the SoftLoad process. Do not attempt to SoftLoad when
GNSS satellite tracking on the unit is required. If the unit is connected to the NovAtel Connect utility, only the
Console and ASCII Message windows may remain open in the Connect Utility.
11.7.1 SoftLoad Commands and Logs
Refer to the
Agriculture Commands and Logs Reference Manual
detailed log and command information.
Command
Description
SOFTLOADRESET
Initiate a new SoftLoad process
SOFTLOADSREC
Send an S-Record to the receiver for the SoftLoad process
SOFTLOADDATA
Send firmware image data to the receiver for the SoftLoad process
SOFTLOADCOMMIT
Complete the SoftLoad process
SOFTLOADSETUP
Send configuration information to the receiver for the SoftLoad process. This command is
not required when working with a *.shex file
Log
Description
SOFTLOADSTATUS
Provides status updates for the ongoing SoftLoad process
Each command and log can be used in abbreviated ASCII, ASCII or binary format, with the exception of
SOFTLOADDATA, which should only be used in binary format.
File Types
Firmware data is stored in *.shex files as ASCII data in the form of S-Records, based on the Motorola S-Record
format. The *.shex file includes a digital signature for the firmware.
11.7.2 Working With S-Records
Each S-Record has a header indicating the type of information contained in the record.
Records beginning with S0, S5 and S7 contain metadata about the firmware image, such as version information
and which card types are supported by the firmware image.
Example S0 Record
S0~V~OM7MR0400RN0000
Example S5 Records
S50000
S503D9FE25
S5033158D5A
Example S7 Records
S70000
S70500000000FA