SMART-MR10 User Manual Rev 0B
Appendix B
Commands
Abbreviated ASCII Syntax:
Message ID: 1
LOG [port] message [trigger [period [offset [hold]]]]
Factory Default:
log com1 rxstatuseventa onnew 0 0 hold
log com2 rxstatuseventa onnew 0 0 hold
log com3 rxstatuseventa onnew 0 0 hold
log aux rxstatuseventa onnew 0 0 hold
log usb1 rxstatuseventa onnew 0 0 hold
log usb2 rxstatuseventa onnew 0 0 hold
log usb3 rxstatuseventa onnew 0 0 hold
Abbreviated ASCII Example 1:
log com1 bestpos ontime 7 0.5 hold
The above example shows
BESTPOS
logging to COM port 1 at 7 second intervals and offset by 0.5
seconds (output at 0.5, 7.5, 14.5 seconds and so on). The [hold] parameter is set so that logging is not
disrupted by the
UNLOGALL
command.
To send a log only one time, the trigger option can be ignored.
Abbreviated ASCII Example 2:
log com1 bestpos once 0.000000 0.000000 nohold
Refer to the
Command Formats
section of the
OEMV Family Firmware Reference Manual
for
additional examples.
1.
In
CDU
there are two ways to initiate data logging to the receiver's serial ports. You can
either enter the LOG command in the
Console
window, or use the interface provided in
the
Logging Control
window. Ensure the Power Settings on your PC are not set to go into
Hibernate or Standby modes. Data is lost if one of these modes occurs during a logging
session.
2.
Only the ASCII/Abbreviated ASCII log table is included in this manual. Please refer to the
LOG
command in the
OEMV Family Firmware Reference Manual
for binary log details.