36
SMART-MR10 User Manual Rev 0B
Chapter 3
Operation
Figure 8: Basic Differential Setup
Reference
Description
1
SMART-MR10 receiver
2
User-supplied 5A fuse
3
User-supplied power supply, for example a battery
4
User-supplied device to COM1
5
User-supplied radio device to COM2
6
User-supplied PC/laptop, for setting up and monitoring, to COM1
System biases can introduce errors. Refer to the NovAtel web site at
http://www.novatel.com/support/
for more information. In most cases you need to provide a data link between the base station and rover
station (two NovAtel receivers) in order to receive corrections. The application of SBAS corrections
to a single receiver are an exception to the base/rover concept. Generally, a link capable of data
throughput at a rate of 9600 bits per second, and less than 4.0 s latency, is recommended.
Once your base and rover are set up, you can configure them as outlined in the configuration examples
in
3.3.1, Base Station Configuration
3.3.2, Rover Station Configuration