34
SMART-MR10 User Manual Rev 0B
Chapter 3
Operation
3.2.2
Communicating with the Receiver Using CDU
Launch the
CDU
program and select
Device | Open
from its main menu. The
Open Configuration
window appears. Figure 7, below, shows an
Open Configuration
window with three possible
configurations already set up. Your configurations may be different or you may have none at all, in
which case, the
Open Configuration
window is empty.
Figure 7: Open Configuration Window
Refer to
CDU
’s help file by selecting the
Help | Contents
menu. Ensure you can see the
Console
and
ASCII Messages
windows by selecting them from the
View
menu.
When the receiver is first turned on, no data is transmitted from the COM ports except for the port
prompt. The console window displays a port name:
[COM1]
if connected to COM1 port
,
or
[COM2]
if connected to COM2 port
,
Any of the above prompts indicate that the receiver is ready and waiting for command input.
1.
You may also have to wait for output from receiver self tests. For example, on start-up,
the OEMV family receiver is set to log the RXSTATUSEVENTA log ONNEW on all
ports. Refer to the
OEMV Family Firmware Reference Manual
for more details.
2.
If you find that
CDU
is unable to locate your OEMV family receiver, it may be that you
have previously used the SAVECONFIG command. In this case, try using a different
COM port to communicate to the receiver. Once communication has been established,
issue the command FRESET STANDARD. You should now be able to use your original
communication port again.