Technical Specifications
Appendix A
SMART-MR10 User Manual Rev 0B
65
A.2
SMART-MR10 Specifications
f.
Typical value. Almanac and recent ephemerides saved and approximate time entered. For more
information, Please refer to the “SETAPPROXTIME” command in the
OEMV Family Firmware
Reference Manual
found on our Web site at
http://www.novatel.com/support/docupdates.htm
.
INPUT/OUTPUT CONNECTORS
SMART-MR10 COM/
PWR
+8 to +36 V DC at 2.5 W (typical while logging)
a
For the cable pinouts and drawings, see
Cable (Part Number 01018515) starting on page 68
Streamlined Cable (Part Number 01018526) starting on page 70
Serial Com Ports
3 RS-232 serial ports (1 port configurable to RS422) [230,400 bps
maximum]
CAN
SAE J1939/ ISO 11783/ ISO 11898 Compliant
Emulated Radar Output
High = Supply Voltage -0.5V Minimum
Low = 0.5 V Maximum
Load = 3K Ohm Minimum
PPS Output
3.3 V CMOS Logic Compatible
MKI Input
3.3 V CMOS Logic/ 5 V Tolerant
Mode Pin
0 to 36 V DC (depending on the desired configuration, the Mode pin
can be left open, connected to ground, or connected to the supply
voltage)
INPUT/ OUTPUT CONNECTOR PROTECTION
Electrical Conducted/
Coupled disturbance
tolerance
ISO 7637-2:2004 (Survives all pulse types)
ISO 15003 (TBD)
LED INDICATORS
More details can also be found in
Section 2.2.2, Status Indicators
PHYSICAL
Size
223 mm x 223 mm x 90 mm height
Weight
2.2 kg maximum
ENVIRONMENTAL
Operating Temperature
-40
°
C to +75
°
C
Storage Temperature
-55
°
C to +90
°
C
Humidity
Not to exceed 95% non-condensing
Immersion
MIL-STD-810F Method 512.4 Procedure 1
Vibration
b
Random
MIL-STD-810F Method 514.5 C17
Sinusoidal IEC
68-2-6
ASAE
EP455, 5.15.2 Level 1 (TBD)
Shock
MIL-STD-810 F Method 516.5
Содержание SMART-MR10-GENERIC