Chapter 3 OEM7 Receiver Operation
OEM7 Installation and Operation User Manual v4
79
l
<PSN> is the product serial number of the enclosure
l
<UTC_Date> is the UTC date in the format YYYY-MM-DD
l
<UTC_Time> is the UTC time in the format HH-MM-SS
Example file name: NOV12001200A_2017-01-10_12-14-34.LOG
When a file is closed, but the receiver does not have a valid time, the file is left with its auto-
matically generated name.
l
The file is created before the
FILECONFIG
command returns a response.
l
Only logs that are published after the log file is open are recorded.
l
Only one log file can be open at a time.
l
Logs requested to the FILE port are still produced even if the log file is closed,
however the logs are not recorded. (This is similar to requesting logs to COM4
when there is not connection to COM4.) If a new log file is opened, recording
of the previously requested logs continues with the new file.
File Rotation
When collecting a large amount of log data over an extended time period, the maximum size
and duration for a log file can be configured using the
FILEROTATECONFIG
command.
If the file duration is set, the log file is closed after the specified duration and a new log file is
created. If the file size is set, the log file is closed after the file reaches the specified size and a
new log file is created. New log files are created and closed until the file system runs out of free
space or logging is stopped. If the
OVERWRITE
mode has been set, the oldest file will be
deleted in order to make room for the new file so data logging can continue.
There is no data loss during the file rotation process and individual logs within the file are not
spread between log files.
For more information about configuring file rotation, refer to the
FILEROTATECONFIG
com-
mand in the
OEM7 Commands and Logs Reference Manual
The maximum size of a log file is 4 GB. Once this size is reached, the log file will close.
Another log file will be created to continue logging.
3.12.3 Logging Using NovAtel Connect
NovAtel Connect is a computer program used to configure and monitor NovAtel receivers.
The Logging Control Window in NovAtel Connect provides an interface to configure logging and
to collect logs from the receiver. The collected logs can be output to one of the receiver com-
munication ports or stored on the computer running NovAtel Connect.
For details about using NovAtel Connect, refer to the Help file available within NovAtel
Connect.
Содержание OEM719
Страница 1: ...OM 20000168 v4 February 2018 OEM7 Installation and Operation User Manual...
Страница 123: ...Chapter 8 NovAtel Firmware and Software OEM7 Installation and Operation User Manual v4 123...
Страница 130: ...APPENDIX A OEM719 Technical Specifications OEM7 Installation and Operation User Manual v4 130 Figure 43 OEM719 Keep outs...
Страница 150: ...APPENDIX B OEM729 Technical Specifications OEM7 Installation and Operation User Manual v4 150 Figure 50 OEM729 Keep outs...
Страница 235: ...OEM7 Installation and Operation User Manual v4 235...