To mix NovAtel format messages and RTCM V3 messages on the same port, leave the interface
mode set to NOVATEL and log out variants of the standard correction messages with a NovAtel
header. ASCII or binary variants can be requested by appending an A or B to the standard mes-
sage name. For example, on the base station:
interfacemode com2 novatel novatel
fix position 51.11358042 -114.04358013 1059.4105
log com2 rtcm1004b ontime 2
1. Interface mode must be set to NOVATEL for the receiver to issue logs with an A or B
suffix.
2. Using the receiver in NOVATEL mode consumes more CPU bandwidth than using the
native differential messages as shown in
3. To find information on how to send multiple commands and log requests from a com-
puter, search our knowledge database available at
.
At the rover, leave the interface mode default settings (interfacemode com2 novatel novatel).
The rover recognizes the default and uses the corrections it receives with a NovAtel header.
The
PSRDIFFSOURCE
command and
RTKSOURCE
command set the station ID values that
identify the base stations from which to accept pseudorange or RTK corrections. They are useful
commands when the rover station is receiving corrections from multiple base stations.
3.4 ALIGN Heading Master and Remote Configurations
ALIGN technology combines two or more receivers to generate high precision heading and pitch
angles between two receivers for real-time navigation.
This section provides instructions for setting up a master station with an ALIGN capable rover
receiver for applications that require heading output. Refer to
, available at
Dual antenna receivers, such as the OEM7720, can provide an ALIGN solution
without additional receivers or configuration.
This section is for applications that require additional rover receivers.
3.4.1 Automatic Set Up for Direct-Wire Connection between Master and
Rover via COM2
The
ALIGNAUTOMATION
command must only be sent to the rover.
ALIGNAUTOMATION ENABLE
or
ALIGNAUTOMATION ENABLE COM2 230400 10 ON
3.4.2 Manual Set Up via COM2
Master:
serialconfig com2 9600 N 8 1 N on
Содержание OEM719
Страница 1: ...OM 20000168 v4 February 2018 OEM7 Installation and Operation User Manual...
Страница 123: ...Chapter 8 NovAtel Firmware and Software OEM7 Installation and Operation User Manual v4 123...
Страница 130: ...APPENDIX A OEM719 Technical Specifications OEM7 Installation and Operation User Manual v4 130 Figure 43 OEM719 Keep outs...
Страница 150: ...APPENDIX B OEM729 Technical Specifications OEM7 Installation and Operation User Manual v4 150 Figure 50 OEM729 Keep outs...
Страница 235: ...OEM7 Installation and Operation User Manual v4 235...