MicroE Optira Installation Manual
Celera Motion
IM-1001 | REV181211
Page 37
©2018 Celera Motion
Step
Action
4.
From the left end of the tape scale inserted in the applicator tool, peel and curl back 50-
75 mm (2-3 inches) of the adhesive backing as shown so that backing separates from
scale before entering tool under the roller. Take care not to touch the adhesive on the
bottom of the tape scale or allow any particle contamination.
Note
:
Do not
peel the blue protective film off at this time.
5.
Place applicator tool and tape scale against benching pins on benching fixture.
Note
: Applicator tool benches the same as the sensor and uses the same holes for the
mounting screws.
Peel and cut back 50-75 mm (2-3 inches) of the adhesive backing
Adhesive backing
separating from
scale before going
under roller