©2018 Celera Motion 

  If removed from the mounting surface for any reason, they should not be used for any 

kind of re-application. This will affect the performance and reliability of the encoder 
system.  

The adhesive on the Optira tape scale is permanent: 

  DO NOT touch the adhesive once the adhesive backing is removed. 

  DO NOT remove the tape scale from the mounting surface once it has been installed.   

  DO NOT reinstall the tape scale if it has already been installed once. If the tape scale is 

removed and reinstalled again, the encoder performance will be degraded. 

  Avoid any contamination to the adhesive. Any particulate matter or contamination trapped 

between the scale and the mounting surface will affect encoder performance. 

  Optira tape scale is not recommended for applications on a radius. Contact MicroE for 

support. 

 

 

Содержание Celera Motion Optira Series

Страница 1: ...MicroE Optira Installation Manual Celera Motion IM 1001 REV181211 Page i 2018 Celera Motion...

Страница 2: ...ll Sensor 8 6 1 1 Sensor Mounting Orientation and Tolerances 9 6 1 2 Top Mounting 9 6 1 3 PCB Mounting 11 6 1 4 Sensor Head Alignment 11 6 1 5 LSB Index Calibration 12 6 2 Install Optional Connector a...

Страница 3: ...Using the Applicator Tool 34 12 0 Linear Glass Scales Installation 43 12 1 Before Installation 43 12 1 1 Items Required for Glass Scale Installation 43 12 1 2 Flowchart for Glass Scale Installation 4...

Страница 4: ...ete system level electronic product is responsible for complying with 21 CFR MicroE Systems encoders contain an infrared laser diode or diodes Emitted invisible laser radiation levels have been measur...

Страница 5: ...ies Encoders Interface Drawings 2 6 Trademarks Optira trademark of Novanta Inc d b a Celera Motion 2 7 Special Conventions Used The following symbols may be used in this document Symbol Description Wa...

Страница 6: ...he Optira design allow easy access to the sensor for service and or replacement For optimal performance and reliability DO follow standard ESD precautions while handling the sensor DO allow proper cle...

Страница 7: ...ment and calibration Design Mounting Is Z Height adjustable Align Sensor No Yes Set Z Height using shim Benching Edge Install Complete LSB Install Scale Calibrate Install Sensor Yes No Yes No Optional...

Страница 8: ...Philips head screws are recommended Do not use slotted head screws which can allow the screwdriver to slip and damage components Tighten screws per torque specification 0 34Nm 3 inch lbs maximum Cauti...

Страница 9: ...s per torque specification 0 34 Nm 3 inch lbs maximum Caution Be careful tightening these screws to avoid damaging nearby components PCB Mount Connector1 Molex part number 501591 1211 0 40 mm 016 pitc...

Страница 10: ...Cable Custom Development Kit Cable with JST Connector and 15 Pin D Sub to connect between Connector and Calibration Board and customer s electronics Z Height Shim Spacer Shim for setting gap between s...

Страница 11: ...nting This section contains instructions for designing the mounting scheme for installing the sensor A benching edge is recommended to locate the sensor to meet mechanical mounting tolerances Refer to...

Страница 12: ...r information in Section 3 0 System Overview For installing the sensor to a PCB go to Section 5 1 3 PCB Mounting Note A scale must be installed before installing the sensor Refer to the Optira Series...

Страница 13: ...riser and the top of the scale 0 493 mm Refer to the Optira Interface Drawing for details 6 Insert the Z Height Shim Spacer between the sensor s riser and the top of the scale 7 Fully tighten the two...

Страница 14: ...e to achieve proper signal strength from the count track and the index track Proper sensor alignment may require minor adjustments to the sensor position with respect to the scale Sensor alignment can...

Страница 15: ...og sensors or digital Optira sensors configured with the 20 m Index Window do not require calibration When to perform calibration When installing the sensor for first time If the sensor is subsequentl...

Страница 16: ...al on the sensor connector pin 8 of J1 or JP1 to ground pin 10 of J1 or JP1 or to ground on the PCB Result The system status LED starts blinking at a regular rate 2 Move the sensor over the index up t...

Страница 17: ...ctly to conductive surface without standoffs Use the board as an indicator of alignment by monitoring the alarm LED Refer to Section 5 1 4 Sensor Head Alignment to match Status Led on sensor and if Al...

Страница 18: ...1 5 g sensor head Sensor Cable ZIF Flat Flexible Cable FFC 10 pins length up to 5 m Signal Levels A B I differential RS 422 compatible A B I single ended Voh min Vcc 0 4 VDC Vol max 0 4 VDC Alarm Voh...

Страница 19: ...Connectors Pinouts The following are the pinouts for the two connectors on the Optira sensor JP1 Low Profile Board to Board Header Connector Manufacturer Part Number Molex 501594 1211 Pin Number Signa...

Страница 20: ...rmination Note Below values are applicable for 5 V models only Digital Analog Outputs Alarm Circuit Example Alarm output is an open collector circuit that is factory programmable either active high or...

Страница 21: ...IM 1001 REV181211 Page 18 2018 Celera Motion 7 5 Board to Board Header Wiring Examples The following are sample customer circuits for connecting to the Optira sensor using board to board mounting 3 3...

Страница 22: ...MicroE Optira Installation Manual Celera Motion IM 1001 REV181211 Page 19 2018 Celera Motion 5 VDC Digital Operation 5 VDC Analog Operation...

Страница 23: ...10 PWR PWR Development Kit Cable 15 Pin D sub 10 Pin JST Cable from Connector Calibration Board to Customer Interface 10 Pin JST Signal 15 Pin D Sub A quad B Analog NC NC NC 1 NC NC NC 2 Pin 6 Alarm A...

Страница 24: ...Incremental Encoder Signals Optional RS 422 compliant circuitry for long cable runs in harsh electronic environments is illustrated below 7 9 Troubleshooting Problem Solution The LED on the sensor doe...

Страница 25: ...PILT Optira Tape Scale Standard Resolution 5000 5 m 2500 2 5 m 1000 1 m 0500 0 5 m 0200 0 2 m 0100 0 1 m 0050 50 nm 0020 20 nm 0010 10 nm 0005 5 nm 0000 Analog 1 Vpp Accessories PI DK Development Kit...

Страница 26: ...Scale Mounting 9 1 Overview The instructions in this manual apply to the following scales for Optira Series Encoders Optira Tape Scale Model PILT Optira Linear Glass Scales Model PILG Optira Rotary Gl...

Страница 27: ...mm not required for installations 300 mm Refer to encoder data sheet or sensor installation manual for details on ordering parts 11 1 2 Pre Installation Information and Precautions Read all instructio...

Страница 28: ...esive once the adhesive backing is removed DO NOT remove the tape scale from the mounting surface once it has been installed DO NOT reinstall the tape scale if it has already been installed once If th...

Страница 29: ...is a simple flowchart showing the main steps in tape scale installation Clean and Inspect Scale Manually Use Applicator Tool Install Tape Scale Prepare Mounting Surface Refer to Design Guide Cut Tape...

Страница 30: ...0 13 mm required between scale benching edge and bottom of mounting surface Benching edge must be parallel to axis of motion to within 05 100 mm Mounting surface flatness to within 003 10 mm 3 Machine...

Страница 31: ...tion Step Action 7 Inspect the mounting surface for any machining irregularities MicroE Systems recommends a surface finish of better than 3 2 micrometers Ra 8 Thoroughly clean the scale mounting surf...

Страница 32: ...ation kit Note Check interface drawing to make sure that the scale is cut to the correct length 2 Securely hold the tape scale close to the shears at an approximate distance of 40 mm 1 inches near the...

Страница 33: ...g methods Manually by hand Using the Applicator Tool Note Use the Design Guide to help you select the method of installation 11 3 1 Install Tape Scale Manually Use the steps in this section to install...

Страница 34: ...5 mm 1 inch of the bottom adhesive backing taking care not to touch the adhesive or allow any particulate contamination Note Be careful not to expose the adhesive backing more than 50 mm 2 inches Do n...

Страница 35: ...scale while the other hand slides evenly along the scale During the sliding motion press the remaining tape on to the mounting surface and against the reference edge and then pull the adhesive backin...

Страница 36: ...hesive is set evenly and permanently Performing this operation more than once is not necessary but will not have an adverse effect 7 Peel off the blue protective film Start the peeling process using a...

Страница 37: ...hile feeding the tape scale to attach to a mounting surface Tape Travel Path The path for the tape scale through the applicator tool is shown in the following diagram Left end of tool Roller Dowel Ref...

Страница 38: ...ds to the Optira encoder as shown below The benching surfaces correspond to the A and B faces shown in the Optira interface drawing Typical Motion Axis Recommended Customer Required Parts The followin...

Страница 39: ...licator tool is shown in the example shown below The left end of the tape scale will go into the applicator tool entry channel first 2 Optira tape scales have four layers blue protective film Inconel...

Страница 40: ...ing tool under the roller Take care not to touch the adhesive on the bottom of the tape scale or allow any particle contamination Note Do not peel the blue protective film off at this time 5 Place app...

Страница 41: ...lation Manual Celera Motion IM 1001 REV181211 Page 38 2018 Celera Motion Step Action 6 Hold applicator tool firmly against benching pins 7 Attach applicator tool using the two mounting screws Benching...

Страница 42: ...lling adhesive backing away from scale 9 Feed tape scale into the applicator tool until the end of the tape is past the roller Place applicator tool along reference edge and firmly press down on mount...

Страница 43: ...pressure motion until all of the tape is installed on the mounting surface Be sure the adhesive backing film does not bunch up and jam inside the tool and exits freely from the exit slot 12 Pull adhe...

Страница 44: ...Celera Motion IM 1001 REV181211 Page 41 2018 Celera Motion Step Action 14 Peel off the blue protective film Start the peeling process using a sharp tool being careful not to damage the scale Pull off...

Страница 45: ...ean using alcohol or acetone and a lint free cotton cloth 16 Precautions If scale damage has occurred the tape scale may need to be replaced Clean the tape scale using alcohol or acetone and a lint fr...

Страница 46: ...available for Optira linear glass scales installation Item Finger Cots or talc free gloves Acetone or isopropyl alcohol Lint free cotton cloths or wipes Epoxy non conductive Stick and disposable surfa...

Страница 47: ...nds a mounting surface flatness of 0 0001 inch inch 3 Thoroughly clean the scale mounting surface and reference edge using a cotton swab or lint free cloth dampened with isopropyl alcohol or acetone R...

Страница 48: ...stallation of new scale 13 2 Cleaning Scales Step Action 1 General Particle Removal Blow off any contamination with nitrogen clean air or a similar gas 2 Contamination Removal Use a lint free cleanroo...

Отзывы: