10.0 Rotary Scales
For details on rotary scales, see the following:
•
Optira Series Encoders Data Sheet
•
Optira Series Encoders Interface Drawing
11.0 Tape Scale Installation
Use the steps in this section to install Optira tape scales.
11.1 Before Installation
Review the information in this section prior to installing tape scales.
11.1.1 Items Required for Tape Scale Installation
You will need the following items available for tape scale installation.
Item
Finger Cots or talc-free gloves
Acetone or isopropyl alcohol
Lint-free cotton cloths or wipes
Epoxy, non-conductive
Stick and disposable surface for stirring epoxy
Shears
1
Tape Applicator Tool
2
Notes
:
4. Recommended: Clauss Part Number 18003.
5. Model PILT-AT: required for applications >300 mm (not required for installations <300 mm).
Refer to encoder data sheet or sensor installation manual for details on ordering parts.
11.1.2 Pre-Installation Information and Precautions
Read all instructions completely before beginning the installation process and follow the
instruction sequence throughout the installation process. The Optira tape scale is a precision
metrological device. Handle it with the utmost care at all times.
•
Avoid bending the tape scale to a radius less than
90 mm (3.5 inches)
•
Avoid twisting the Optira tape scale.
•
The Optira tape scale is protected by a blue film on
the top that prevents contamination and damage to
the grating pattern during installation.
•
DO NOT let any sharp object touch the tape scale
after the blue protective film is removed.
•
Once the adhesive on the tape scale is exposed (by
removing the adhesive backing), do not touch the
adhesive or allow any contamination to come into
contact with it.
•
Optira tape scale is designed for one time installation only.
Minimum bending radius
90 mm (3.5 inches)