MicroE Optira Installation Manual
Celera Motion
IM-1001 | REV181211
Page 39
©2018 Celera Motion
Step
Action
8.
Start feeding tape scale with blue protective film under the roller and into the entry slot
while pulling adhesive backing away from scale.
9.
Feed tape scale into the applicator tool until the end of the tape is past the roller. Place
applicator tool along reference edge and firmly press down on mounting surface.
Remove adhesive backing before going under roller
Tape scale fed past front tool roller
Applicator tool correctly
configured for installation
Attached mounting screws
Feed tape scale under roller