Output Code:
When this statement’s comparison is found true, this 8-bit value will be bitwise
OR’ed with the Output Code values of all other true statements to form the
threshold output. Any set bits remain latched until a user issues a
Reset Latch
. If no
statements are true the threshold output is zero.
The value displays in hexadecimal, format 0x00. A user may type output codes
in hexadecimal format or in decimal. Bit pattern representing each thresholding
statement number are in the following table.
Table 6.3—Bit Patterns for Thresholds Breached
#:
Bit Pattern
#:
Bit Pattern
#:
Bit Pattern
#:
Bit Pattern
0:
0x00000001
4:
0x00000010
8:
0x00000100
12:
0x00001000
1:
0x00000002
5:
0x00000020
9:
0x00000200
13:
0x00002000
2:
0x00000004
6:
0x00000040 10: 0x00000400
14:
0x00004000
3:
0x00000008
7:
0x00000080 11: 0x00000800
15:
0x00008000
Get Statuses:
Click the
Get Statuses
button to update the static display of the threshold status. If
a threshold is unsatisfied, the threshold numbers are crossed out.