Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-60
Table 8.2—“set” Fields
Field
Long Name
User
Read/
Write
Description
Example
Contents
Type
cpf
Counts per Force
Read
Calibration counts per force
unit.
1000000
32-bit
unsigned
integer
cpt
Counts per Torque
Calibration counts per
torque unit.
peakPos0
PeakLoadsPosF
x
All-time peak positive force/
torque loads that are in F/T
counts.
2395927
32-bit
unsigned
integer
peakPos1
PeakLoadsPosF
y
624574
peakPos2
PeakLoadsPosF
z
0
peakPos3
PeakLoadsPosT
x
0
peakPos4
PeakLoadsPosT
y
159210
peakPos5
PeakLoadsPosT
z
74910
peakNeg0
PeakLoadsNegF
x
Read
All-time peak negative
force/torque loads that are
in F/T counts.
-988570
32-bit
unsigned
integer
peakNeg1
PeakLoadsNegF
y
-2099525
peakNeg2
PeakLoadsNegF
z
-91487584
peakNeg3
PeakLoadsNegT
x
-48751
peakNeg4
PeakLoadsNegT
y
-12854
peakNeg5
PeakLoadsNegT
z
0
sensorHwVer
N/A
Read
The version of the sensor
hardware
0
16-bit integer
adcRate
N/A
Read
and
Write
The ADC update rate in Hz.
The ADC rate must be one
of the following in units of
Hz:
488
976
1953
3906
7812
976
16-bit integer
rdtRate
N/A
Read
and
Write
The RDT transmission rate
in units of Hz. The RDT
transmission rate must be 1
to the adcRate.
100
16-bit integer
rdtSize
N/A
Read
and
Write
The number of RDT
records to include in
each UDP packet that is
transmitted.
1
16-bit integer
filTc
N/A
Read
and
Write
The IIR filter shift value.
0
8-bit integer
calib
N/A
Read
and
Write
The calibration to use:
0 or 1
This bit controls which of
the two sets of calibrations
are displayed in the
preceding fields.
0
8-bit integer