Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-26
5.2 LED Normal Operation
5.2.1 Sensor Status LED
One LED signals the health status of the sensor as follows:
Table 5.2—Sensor Status LED
LED Color
State
Description
Off
No power
Electricity is not supplied to the sensor.
Green
Normal operation
The sensor’s electronics are functioning and
communicating.
Amber
1
Sensing range
exceeded
Indicates that an F/T axis is out of range.
Reduce the applied load or use a larger
calibration if available.
Red
(flash at 1 Hz
speed)
Calibration error
Sensor is not referencing a calibration range
or has a checksum error.
Red
(flash at 10 Hz
speed)
Communication error
The sensor is not able to communicate data
over the communication protocol.
Red
(solid)
Status code error
For more information on the error set,
refer to
.
Note:
1. Amber is when both green and red LEDs are on.
5.2.2
Diag LED
One LED signals the diagnostic status of the Ethernet Axia sensor interface as follows:
Table 5.3
—Diag LED
LED Color
State
Description
Green Blinking Pre-operational
Defined by the communication/protocol
standard.
Green
Operational
No errors are found.
Red
Error
Indicates an error reported by the internal
electronic components.
Also, after a UART error, the LED stays red for
five seconds.
5.2.3
Ethernet Link/Activity LED
One LED signals link/activity on the communications port as follows:
Table 5.4—L/A LED
LED Color
State
Description
Off
No power or no link
activity
Link/activity is not detected.
Green
Link activity
This light stays green
for 5 seconds after any link activity.