![Norton Assa Abloy D6001DE-L Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/norton/assa-abloy-d6001de-l-series/assa-abloy-d6001de-l-series_installation-instructions-manual_1709084005.webp)
Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
5
D6001DE-L Double Unit Series (Double Egress)
Power Operator
Prepare Frame and Doors
Figure 1
Pull Side
Push Side
Left Hand
PULL
Right Hand
PULL
Become familiar with operator components and fasteners.
It is recommended that components remain in boxes
until installed. Verify there is minimum ceiling clearance for operator installation before proceeding. (Figure 1)
A. Prepare frame.
Verify correct installation . (Figure 2)
NOTE: These instructions are for Pair of Doors,
where door on right is a Push door and door
on left is a Pull door. Arms included with this
assembly will fail if both doors are Pull doors
or if both doors are Push doors. Please contact
Customer Service or your local distributor if
this is the case.
1 .
Frame header MUST be flat / without twists.
Backplates can be used as reference .
NOTE: If frame is not flat or is twisted,
additional steel back plates or shimming is
required. Failure to mount units properly can
result in improper function of operator or
inability to snap on covers.
2 . Mark center of opening on frame header
between jambs .
3 . Using chart, mark from center of opening to
left
.
(Figure 3)
NOTE: Template provided on page 29.
4 . Measure 1" up from frame rabbet and mark at
Dim A and Dim B locations .
5 . Drill holes .
6 . Using supplied backplate screw pack in Box 1,
insert screws into prepared mounting holes .
For Metal Frame:
Use two (2) 1/4-20 x 1" flat
head machine screws .
For Wood Frame:
Use two (2) #14 x 1-1/2" flat
head self-drilling screws .
NOTE: Do not tighten mounting screws at
this time. Leave 5/16" minimum (thickness of
backplate) between frame face and back of
screw head.
OR
Figure 2
Figure 3
Center of Opening
Dim B
Dim A
1"
Door Size
Dim A
Dim B
Pair of 36" doors:
5-9/16" (141mm)
30-9/16" (776mm)
Pair of 38" doors:
7-9/16" (192mm)
32-9/16" (827mm)
Pair of 40" doors:
9-9/16" (243mm)
34-9/16" (878mm)
Pair of 42" doors:
11-9/16" (294mm) 36-9/16" (929mm)
Pair of 44" doors:
13-9/16" (344mm) 38-9/16" (979mm)
Pair of 46" doors:
15-9/16" (395mm) 40-9/16" (1030mm)
Pair of 48" doors:
17-9/16" (446mm) 42-9/16" (1081mm)