D6001DE-L Double Unit Series (Double Egress)

 Power Operator

Controller Interface Description

Screen 1

Adjustments

Default

Description

Mount:

Push or Pull

Push

Side of opening operator is mounted on

Hold Open:

0 - 30 sec in 1 sec increments

4s

Amount of time door will stay in full open position after an activation

Open Delay 

(previously Start 

Delay):

0 - 10 sec in 1 sec increments

0s

Time before operator begins to open door . Allows accessories time to function and not hinder 

opening of door

Latch Rtrct:

OFF, 3 - 45 sec in 5 sec increments

OFF

Amount of time power is supplied to a latch retraction device

Home:

see Setting Open Position

-

Used to set Home position and Fully Open position of door

Vestibule:

OFF, 5 - 30 sec in 5 sec increments

OFF

Amount of delay for opening 2nd vestibule door

Push:

OFF or PushNGo

OFF

Turn on or off Push N Go feature . If On, a slight push or pull of the door starts automatic 

opening .

Open Speed:

0 - 100% in 1% increments

120

How fast door opens to full open position

Close Speed:

0 - 100% in 1% increments

80

How fast motor returns to home position . As Latch and Sweep on closer are adjusted, 

adjustments may be needed for Close Speed to assure closer is not trying to backdrive motor .

Errors:

not adjustable

-

Error code seen by controller . See Page 17 for Controller Error Codes .

Screen 2

Adjustments

Default

Description

Door Feedback:

not adjustable

-

General feedback . Includes Door State, Door Position, Motor Position, Open Limit, Close Limit

Drive Feedback:

not adjustable

-

General feedback . Includes Bus Voltage, Bus Current, Frequency

Usage:

not adjustable

-

General feedback . Includes Open Time, Close Time, Days, Cycles, Firmware Rev

Single:

Single Door, Dble:Follow, 

Dble:Master, Dble:Mast Coord

Single

Set on Single for a single, stand alone door. Dble:Follow for Follower door on pair of doors. 

Dble:Master for Master door on a pair of doors. Dble:Mast Coor for Master door on a pair of 

doors when door coordination is needed .

MastStopOffset:

0-500

180

Adjustable point where Master Coord door will stop and wait for Follower door to fully close 

so Follower does not contact astragal attached to Master Coord door

Follow Delay:

0-5 sec in 1 sec increment

0s

Amount of delay for Follower door after Master door has started to open

PDET Option:

On, Off

Off

On or Off for 585 Presence Detector

DT:

Standard, 

SS1:Stall,

SS1:Return Open,

 

SS1:Stall /Open

Stnd

Standard is Door Toggle. SS1:Stall - when sensor detects an obstruction in opening as door is 

closing, door will stall until obstruction is removed. SS1:Return Open – when sensor detects 

an obstruction in opening as door is closing, door will stop and return to full open position 

until obstruction is removed. SS1:Stall/Open – when sensor detects an obstruction in opening 

as door is closing, door will stall until obstruction is removed and door will return to full open 

position .

A2:

Standard, 

SS2:Stall,

SS2:Return Home, 

 

SS2:Stall /Home

Stnd

Standard is Activation mode - just like A1 activation. SS2:Stall – when sensor detects an 

obstruction in opening as door is opening, door will stop until obstruction is removed . 

SS2:Return Home – when sensor detects an obstruction in opening as door is opening, door 

will stop and return to full closed position until obstruction is removed. SS2:Stall/Home 

– when sensor detects an obstruction in opening as door is opening, door will stop until 

obstruction is removed and door will return to full closed position .

Rly2:

Alarm, Activation, On Opened, On 

Closed

Alarm

How Relay 2 is used: Alarm - used with above Alarm Delay; Activation - acts as an additional 

NO/NC contact; On Opened - relay trips (closed contacts) when door is in opened position; 

On Closed - relay trips (closed contacts) when door reaches fully closed position .

Alarm Delay:

OFF, 30 sec, 60 sec

OFF

Used only for alarm accessories

Slow Speed:

0 - 100% in 1% increments

55

Speed up or slow down door during last few degrees of opening

Hold Speed:

0 - 100% in 1% increments

55

Increase or decrease hold open force (when in “ON” position only, not “H/O”) to compensate 

for spring force, wind conditions, etc .

Obst Delay:

0 - 5 sec in 1 sec increments

3s

Obstruction Delay: amount of time operator will push against an obstruction before closing if 

during an opening cycle or reopening and trying to close again if during a clocking cycle .

Содержание Assa Abloy D6001DE-L Series

Страница 1: ...0SUP Power Module Sub assembly 6001PM Closer Assembly 7500LAP Pour la version francaise voir www nortondoorcontrols com READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS This product can expose...

Страница 2: ...rs can be installed and adjusted to conform with A D A regulations ANSI A117 1 These door controls permit door assemblies to conform to the requirements of this specification for buildings and facilit...

Страница 3: ...hers required Closing When the hold open time has elapsed the door closer will close the door automatically The door will slow to low speed at latch before it reaches the fully closed position The doo...

Страница 4: ...emplate information based upon use of 5 maximum width butt hinges Frame reveal is 2 1 4 to 4 3 4 for push arm and 1 8 to 3 for pull arm Before beginning the installation verify that the door frame is...

Страница 5: ...ckplates can be used as reference NOTE If frame is not flat or is twisted additional steel back plates or shimming is required Failure to mount units properly can result in improper function of operat...

Страница 6: ...igure 5 6 Using backplate as template mark conduit slot and Dim D mounting hole Figure 5 NOTE Dim D should be 1 up from frame rabbet if backplate is properly aligned 7 Drill hole for mounting screw at...

Страница 7: ...between backplate and wall above header is HIGHLY recommended Material must comply with local codes Failure to properly secure top of backplate could result in operator being allowed to rock during op...

Страница 8: ...ge edge of frame Slide each LAP over two 2 screws and tighten Figure 11 NOTE LAP for left door should have PUSH label and door closer valves should point toward chain LAP for right door should have PU...

Страница 9: ...mbly so two 2 conduit holes are at bottom and text on wire input label is legible Figure 13 2 Secure assembly to backplate using four 4 8 32 x 5 16 Phillips head screws Figure 13 WARNING BUILDING POWE...

Страница 10: ...ne way Install Operator Figure 16 Access Door Union Assembly View From Floor Spacer Spacer Union Assembly Mounting Screw typical Figure 17 Power Module Sub assembly 4 Pin Black Connector Power Module...

Страница 11: ...ugh shoe and into sex bolts Figure 19 NOTE Orient shoe with long side of shoe toward hinge Figure 20 View from ceiling looking downward 1 Open left door 2 Slide forearm into main arm adjusting tube Fi...

Страница 12: ...as shown Figure 28 4 Secure arm to pinion with 1 4 20 x 1 2 screw and countersunk patch washer Figure 27 5 Insert stud on arm into slider in track by pressing clip on backside of slider onto stud Fig...

Страница 13: ...door open When finished slide access door closed and reinsert 6 Torx flat head screw to secure door Figure 32 Adjustments A Adjust mechanical closer features on each operator NOTE Make necessary mech...

Страница 14: ...ight to increase decrease value NOTE Values will auto save 3 seconds after adjustments Figure 33 Figure 34 View From Floor Union Assembly Selector Mode Switches WARNING Door may begin to move immediat...

Страница 15: ...e set Master door will open slightly before Follower door during opening cycle Upon closing if Master door reaches a set door opening position MasterStopOffset and Figure 35 Union Assembly Switches Fo...

Страница 16: ...ackplate verify backplate is not warped or twisted Additional support or shimming may be required See Sections A B under Prepare Frame and Door WARNING Make sure no wiring is loose or can be caught by...

Страница 17: ...ice connected to Aux 1 is sending constant signal Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal Aux 3 Stuck Activation device connected to Aux 3 is sending constant signa...

Страница 18: ...doors when door coordination is needed MastStopOffset 0 500 180 Adjustable point where Master Coord door will stop and wait for Follower door to fully close so Follower does not contact astragal attac...

Страница 19: ...d Function with Switches For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed Fail Secure Electric Strike 24VDC Wiring For Master Follow...

Страница 20: ...o NC For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed and latched Activating switch will energize exit device and door will automati...

Страница 21: ...losed Activating switch will open door Door will remain in indefinite hold open until activating switch is activated a second time causing door to close Change Factory Pre Wiring to Illustration Below...

Страница 22: ...be used to connect inverters Doors are normally closed and latched Fire Alarm activation will retract exit device latch bolt and door operator will open door Door will remain open until the Fire Alarm...

Страница 23: ...hed Activating wireless switch or hand held wireless transmitter will open door Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causi...

Страница 24: ...e normally closed and latched Activating outside door switch will open outside door After vestibule time delay has elapsed a signal will be sent to inside door which will open Activating inside door s...

Страница 25: ...teps 1 4 Hand Held Configuration depress push plate to activate transmitter 4 Attach transmitter to inside of electrical box and complete installation Removing Transmitter Code s Single Transmitter Co...

Страница 26: ...sence Detector senses something in opening door will not close NOTE Presence Detector and or sensors CANNOT be used to active opening cycle of door To activate presence detector functionality On inver...

Страница 27: ...roller screen If DT is set to Standard this is normal Door Toggle mode and will not work with Presence Sensor set to Stall door closing will stall until presence not sensed set to Return Open presence...

Страница 28: ...reaches open position door drifts further open Decrease Hold Speed on controller see pages 14 and 18 until door stops drifting When door reaches open position door bounces Decrease Slow Speed on contr...

Страница 29: ...opyright 2020 ASSA ABLOY Accessories and Door Controls Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls...

Отзывы: