Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
14
D6001DE-L Double Unit Series (Double Egress)
Power Operator
Power Operators
1 . Remove #4-40 Phillips screw to open door on union assembly
and place each selector mode switch in ‘OFF’ position .
(Figure 33)
2 . Turn On/Off switch to ‘OFF’ position on conduit assembly .
(Figure 33)
3 . Turn on building power .
4 . Turn On/Off switch to ‘ON’ position on conduit assembly .
See page 18 for controller adjustment options .
• To scroll through menu items, push up or down on joystick .
(Figure 33)
• To change setting of a menu item, when cursor is on that
item, push joystick left/right to increase/decrease value .
NOTE: Values will auto-save 3 seconds after adjustments.
Figure 33
Figure 34
View From Floor
Union Assembly
Selector Mode Switches
WARNING: Door may begin to move
immediately when power is applied to unit.
An open union assembly door has potential to
pinch fingers if hand is not withdrawn quickly
when switching on power.
5 . Set ‘HOME’ procedure for both doors .
• With door closed and union assembly selector mode
switch in “OFF” position, use joystick to scroll down
menu on LCD screen to “Home”.
• Push in on joystick to activate menu feature . Display
changes to “Set Close Limit”.
• Push in on joystick again, while door is still closed,
to set Home or closed position (Figure 34) . Display
changes to “Set Open Limit”.
• Open door to desired open position (Figure 34) and
push in on joystick again . Display changes to
“Closing to Home”.
• Allow door to fully close again (Figure 34) . Display
changes to “Home”.
NOTE: Values will auto-save.
Conduit Assembly
On/Off Switch
LCD
Screen
Joystick
LCD
Screen
Joystick