Power Operator
B. Install Main Arm.
A. Mount Forearm and Shoe.
Install Arms to Left Door
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
1 . Using previously prepared holes in
door, install two (2) 1/4-20 x 1-5/8"
screws through shoe and into sex
bolts . (Figure 19)
NOTE: Orient shoe with long side of
shoe toward hinge. (Figure 20)
View from ceiling looking downward
1 . Open left door .
2 . Slide forearm into main arm
adjusting tube . (Figure 21)
3 . Place square of main arm onto closer
pinion . (Figure 21)
NOTE: Pinion flat should be aligned
as shown. (Figure 22)
4 . Attach main arm to pinion with
screw then tighten with 7/16"
wrench . (Figure 21)
5 . With door closed, rotate main arm
away from hinge until forearm is
perpendicular (90 degrees) with
door . (Figure 23)
6 . While holding arm in position,
secure forearm to adjusting tube
with forearm screw . (Figure 24)
View from ceiling looking downward
Long Side
of Shoe
Hinge
Forearm
Main Arm
90º
Pinion
Screw
Main Arm
Adjusting Tube
Forearm