background image

2A. Installation Sequence Continued

Step 5: Install main arm onto pinion shaft of unit at a 90° angle to the 

door  frame.    Align  arm  mark “S”  with  the  flat  corner  of  the 
pinion shaft square.  (See Fig. 3 below.)

Step 6: Secure main arm to pinion with 1/4-20 Flange Head Screw 

provided.  Tighten screw with 7/16" wrench or socket.

Step 9:

to 

increase door closing power. Door control is shipped set at 
midpoint of power setting. Maximum closing power can be 
achieved with 8 (360°) clockwise turns of the power 
adjustment screw.

Step 7: Mount arm shoe to door using 2 1/4-20 screws & sex nuts 

provided with screw pack.

Step 8: PRELOAD ARM (See Fig. 4, below):  Remove 1/4-20 hex 

head screw on adjusting rod and insert adjusting rod into 
arm slide.  Reinstall 1/4-20 screw and leave loose.  Rotate 
main arm in direction away from the hinge edge until the 
adjusting rod and arm slide are perpendicular (at a 90° 
angle) to the door frame. Tighten the 1/4-20 hex head screw 
on the adjusting rod to secure arm in this new position.

Adjust closing power of unit (See Fig. 5) - Using a 1/8” allen 
wrench, turn the power adjustment shaft clockwise 

Step 10: Adjust Hydraulic valves using a 1/8” hex wrench to obtain 

proper door closing speeds.  See following illustrations.  Refer 
to Table 1 on page 5 for recommended minimum opening / 
closing times per ANSI/BHMA A156.19.

Note: A.D.A. requires that from an open position of 70°, 
the door will take at least 3 seconds to move to a point 
3” (75mm) from the latched position
, measured at the 
leading edge of the door.

Step 11: Make wiring connections using Wiring Instructions on Page 

below and on Page 8.

Closing Cycle – Make adjustments, as necessary, to the 
Sweep Speed "S" valve and Latch Speed "L" valve. See Fig. 
6 below for location of valves. Turn valves clockwise to reduce 
speed, counter clockwise to increase speed.

Opening Cycle – Adjust Backcheck, "B" valve, as 
necessary, for hydraulic resistance to door opening in the 
backcheck range. See illustration at bottom of this page for 
location of valve.

NOTE: Too much Backcheck, "B" valve, can affect the 
operation of the units pump, preventing units 
from fully 
opening the door. This valve may require fine tuning 
after all other adjustments have been made.

R

L

Y

S

Z

Arm Mark

Pinion Flat

Figure 3

Adjusting

Rod

Arm

Slide

Door

Shoe

Main
Arm

Figure 4

Adjusting

Rod

Arm

Slide

Door

Shoe

Main
Arm

Power
Adjustment

1/8"

Hex

Key

Increase
Power

Decrease
Power

Figure 5

1/8"

Hex

Key

Slower
Closing

Faster
Closing

Closing Cycle

Closed

10°

e

g

n

a

h

ct

a

L

e

g

n

a

R

 

p

e

e

w

S

1/8"

Hex

Key

Increase
Cushion

Decrease
Cushion

Opening Cycle

Backche

ck

g

n

i

n

e

p

O

Sweep Valve

Latch Valve

Backcheck

Valve

Figure 8

Page 7 

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Содержание 5700 LEO series

Страница 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Страница 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Страница 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Страница 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Страница 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Страница 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Страница 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Страница 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Страница 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Страница 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Страница 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Страница 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Страница 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Страница 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Страница 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Страница 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Отзывы: