background image

Low Voltage

Control

Wiring

Incoming

Power

Optional Bracket
(for surface wiring)

Ground
Lead

Power
Leads

Ground
Screw
(Green)

Cable
Clamps

Conduit
by Others
(from top)

“T1” Power
Input
Terminal

24

23

22

25

HOT

COM

Breaker Switch

T1 Terminal
Block

4.  Final Electrical and Mechanical Setup

A. Confirm all mechanical adjustments have been made 

and wiring connected per Page 7 and 8.

B. Turn on facility’s main circuit breaker.
C. Turn power to unit on at the Unit Power Switch and 

turn the Breaker Switch to “RESET”.

D. Using a short jumper cable, jump terminals 1 and 2, 

see Fig. 2 below, to activate unit.  When door 
reaches 20°, switch Breaker Switch to “OFF” 
position cutting power to the unit.  Allow door to 
fully close (door may be manually pulled closed).

1
2
3
4

1
2
3
4

Figure 2

3. Input Power Configurations

CONCEALED WIRING

SURFACE  WIRING

Ground Wire Connection – Ground wire must be secured to backplate 
under head of (green) ground screw .

Terminal

Description

HOT

25

23

24

22

COM

Common power lead

Hot power lead

Circuit Breaker

Switch

Circuit Breaker

Common connection to Circuit Breaker / 
Inverter

Thread  conduit  fitting(s)  into  backplate  as  shown.    A  second 
conduit fitting is required for low voltage control wiring.  CHECK 
LOCAL CODES.  Pull conduit out of header and attach to conduit 
fittings before mounting  Secure operator to door frame.  Attach 
incoming  ground  wire  to  backplate  with  ground  screw  as 
illustrated in “Surface Wiring” illustration to the Right.

Thread  conduit  fitting(s)  into  backplate  as  shown.    A  second 
conduit fitting is required for low voltage control wiring.   CHECK 
LOCAL CODES.   Pull conduit out of header and attach to conduit 
fittings  before  mounting    Secure  operator  to  door  frame.  Attach 
incoming ground wire to backplate with ground screw as illustrated 
below.

Breaker 
Switch

Unit Power Switch

Page 8 

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Содержание 5700 LEO series

Страница 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Страница 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Страница 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Страница 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Страница 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Страница 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Страница 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Страница 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Страница 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Страница 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Страница 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Страница 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Страница 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Страница 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Страница 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Страница 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Отзывы: