Note: Door must be visible by person
operating activation switch(es)
Door Opening
Angle
Dim “A”
Up to 110°
111° to 180°
15-1/2 (394)
13-1/4 (337)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in hollow
metal doors and frames is charted on Page 2.
• Do not scale drawing.
• Right hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges. A separate
template is required for other conditions.
• Maximum frame reveal is 6-7/8” (175mm) for this
application.
• Conduit hole nearest the hinge is suggested for 120
VAC power input.
2” (51mm)
Min.
Frame Face
1-1/8”
(29)
1-1/4
(32)
1-7/16
(37)
11
(279)
22
(559)
7-9/16
(192)
13-7/16
(341)
1-1/8
(29)
C
L Hinge
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8 (23) Dia.
(2 Places)
3/8 Dia.
Sex Nuts
(3 Places)
Frame
Rabbet
Frame
Stop/Soffit
3
(76)
13-13/16
(350)
1/2
(13)
A
11-11/16
(297)
6”
(152mm)
Min.
Clearance
14-3/16
(360)
12-15/16
(329)
13-13/16
(351)
Right Hand Door
opening to 110° shown.
5/8
(15.9)
Stop
1. Hinge (Pull) Side Mounting Instructions
Step 1: Determine hand of door from illustration on upper right of this
page.
Step 2: Using template above locate and prepare holes in the frame &
door:
Frame
A. Prepare six (6) holes for 1/4-20 machine screws or
No. 14 x 2-3/4" (70mm) wood screws. Blind rivet nuts (by others)
are suggested for unreinforced hollow metal frames or for
aluminum frames.
B. Concealed Wired Units Only: Two (2) 7/8" (22mm) diameter
holes for conduit, for power input and for switch/sensor wires.
NOTE: On new construction these holes will generally be drilled
by the frame supplier at their shop or at the time the frame is
installed in the wall.
Door
C. Prepare three (3) holes for 3/8" diameter sex nuts. Standard units
are supplied with sex nuts and screws for 1-3/4" (44mm) thick door.
Sex nuts and screws for other door thicknesses are available to
order.
Step 3: Remove cover from the unit and set cover & cover screws aside.
Step 4: Mount unit to door frame. Select A or B below.
A. Concealed Wired Units Only:
B. Surface Wired Units Only:
(Continue to next page.)
Connect conduit to frame side of
backplate. Fasten unit to door frame (seven screws).
Fasten unit to door frame (seven
screws). Mount conduit bracket (found in screw pack) to unit’s
backplate with two screws provided. Connect wiring conduit to
bracket.
1A. Installation Sequence
Left
Hand
Door
Right
Hand
Door
2” (51mm)
Min. Frame
Face
Frame Reveal
Door
6” (152mm)
Min. Ceiling
Clearance
1-3/4” (44mm) Min.
2-1/4” (57mm) Max.
Door Thickness
Please verify desired mounting
requires Hinge (Pull) Side
application as shown on this
template.
Page 4
ASSA ABLOY
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9357-0008-020 (Rev 3)