background image

Door Opening

Angle

Dim “A”

Dim “B”

Up to 110°

111° to 170°

12 (305)

9-1/2 (241)

13-1/4 (337)

15-3/4 (400)

Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in 

hollow metal doors and frames is charted at the 
left of this page.

• Do not scale drawing.
• Left hand door shown.
• This template information based upon use of 5" 

(127mm) maximum width butt hinges or 3/4" 
(19mm) offset pivots.  A separate template will 
be supplied for other conditions.

• Maximum frame reveal is 7” (178mm) for this 

application.

• Conduit hole nearest to hinge is suggested for 

120 VAC power input.

1-11/16

(43)

1-1/4

(32)

11/16

(17.5)

1-3/4

(44)

12-15/16

(329)

7-9/16

(192)

13-7/16

(341)

3/8

(10)

C

Hinge or Pivot

1/4-20 Machine Screws
or No. 14 Wood Screws

(6 Places)

7/8

(22)

(Conduit Holes - 

2 Places)

       Dia.

Frame

Rabbet

Frame
Stop/Soffit

A

13-13/16

(351)

1/2

(13)

B

5-1/4”

Min.

Clearance

11-11/16

(297)

3/8

(19)

14-3/16

(360)

13-13/16

(351)

Left Hand Door
open to 110° shown.

5/8

(15.9)

Stop

Sex Nuts

(2 Places)

2. Stop (Push) Side Mounting Instructions

2A.  Installation Sequence

Left

Hand

Door

Right
Hand

Door

1-1/2” (38mm)

Min. Frame Face

Frame Reveal*

Door

5-1/4” (133mm)

Min. Ceiling

Clearance

1-3/4” (44mm) Min.

2-1/4” (57mm) Max.

Door Thickness

*For frame reveals less than 3" (76mm) the 
arm adjusting rod can be field cut to a length 
of 9-1/2" (241mm) measured from centerline 
of connecting link bushing assembly. 

Note: Door must be visible by person operating activation switch(es)

Step 1: Determine hand of door from illustration on upper right of this 

page.

Step 2: Using template above locate and prepare holes in the frame & 

door:

Frame
A. Prepare six (6) holes for 1/4-20 machine screws or No. 14 x 2-3/4" 

(70mm) wood screws. Blind rivet nuts (by others) are suggested 
for unreinforced hollow metal frames or for aluminum frames.

B.    Concealed Wired  Units  Only:  Two  (2)  7/8"  (22mm)  diameter 

holes for conduit, for power input and for switch/sensor wires. 

   NOTE: On new construction these holes will generally be drilled 

by the frame supplier at their shop or at the time the frame is 
installed in the wall.

Door

C.   Prepare two (2) holes for 3/8" diameter sex nuts. Standard units 

are supplied with sex nuts and screws for 1-3/4" (44mm) thick 
door.  Sex  nuts  and  screws  for  other  door  thicknesses  are 
available to order.

Step 3:  Remove  cover  from  the  unit  and  set  cover  &  cover  screws 

aside.

Step 4:   Mount unit to door frame.  Select A or B below.

A. Concealed Wired Units Only:   

B.  Surface Wired Units Only: 

Connect conduit to frame side of 

backplate.  Fasten unit to door frame (six screws).

Fasten unit to door frame (six screws).  

Mount conduit bracket (found in screw pack) to unit backplate 
with two screws provided.  Connect wiring conduit to bracket.

Please verify desired mounting 

requires Stop (Push) Side 

application as shown on this 

template.

Page 6

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Содержание 5700 LEO series

Страница 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Страница 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Страница 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Страница 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Страница 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Страница 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Страница 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Страница 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Страница 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Страница 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Страница 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Страница 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Страница 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Страница 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Страница 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Страница 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Отзывы: