Fail Secure / Fail Safe Electric Strike Wiring

120VAC
Supplied by
Others

-

+

DC or AC

Output

A

C or DC

Electr

ic Str

ik

e

+

-

Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary 
dry contacts

Notes:
1.Power input to Door Operator Unit is at “T1” 

Power Input Terminal (not shown) 120VAC 
60Hz.

2.Unit’s Relay Rating for strike interface: 

30VDC @ 1A or 125VAC @ .5A

Operation:

•  
•   

Activating switch will unlock the electric strike 

and the door will automatically open.  Door will 
close after hold open time delay has elapsed

•  

For Fail Secure Strike - The door will remain 

locked during power failure

• 

For  Fail  Safe  Strike  - The  door  will  remain 

unlocked during power failure.

Door is normally closed and latched.

1

2

3

4

1

2

3

4

JMP503

NC

NO

Jumper Settings
Place jumper to upper 
position for normally 
closed operation or to 
lower position for 
normally open operation.

Fail Safe Electromagnetic Lock 24VDC Wiring

1

2

3

4

1

2

3

4

Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary 
dry contacts

+

-

24VDC Electromagnetic Lock
(Fail Safe)

Operation:

•  
•  

Activating switch will cut power to mag lock and the door will automatically 

open.  Door will close after hold open time delay has elapsed.

•  

The door will  unlock during power failure.

Door is normally closed and latched.

Notes:
1.Power input to Door Operator Unit is at “T1” 

Power Input Terminal (not shown) 120VAC 
60Hz.

2.Unit’s Relay Rating: 30VDC @ 1A or 

125VAC @ .5A

Jumper Settings
Place jumper to upper 
position for normally closed 
operation or to lower position 
for normally open operation.

JMP503

NC

NO

120
VAC

Ground

COM

HO

T

L       N

(AC)

-V    +V

ADJ

+

Optional 1.1A 24V 

Power Supply

Page 11 

ASSA ABLOY

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Содержание 5700 LEO series

Страница 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Страница 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Страница 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Страница 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Страница 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Страница 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Страница 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Страница 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Страница 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Страница 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Страница 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Страница 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Страница 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Страница 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Страница 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Страница 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Отзывы: