NAVIGAT X Mk 2
056341 Rev. AA
8: Gyroshpere Installation and Service
Page 8-15
13) Take the protective capsule containing the empty phial of mercury and in-
sulating fluid from the installation and replacement parts kit. Remove the
phial from the capsule and open it.
10) Unscrew the 4mm Allen-head screws at-
taching the two halves of the gyroshere
container.
11)
Put the screws and washers aside, mak-
ing sure they won't be lost or fall to the
ground.
12) Take off the upper section of the gyro-
sphere container and place it upside
down on the work surface.
Caution
Take care not to damage the contact pins.
14) Assemble the syringe and cannula. In-
sert the syringe into the recess of the gy-
rosphere. Draw up the mercury and insu-
lating fluid completely.
Hg
Warning
Spilt mercury will evaporate and give off poisonous fumes.
Collect spilt mercury with the syringe provided in the installation and replace-
ment parts kit and seal it in the phial for the mercury and insulating fluid.
Содержание Sperry Marine NAVIGAT X MK 2
Страница 8: ...056341 Rev AA NAVIGAT X Mk 2 vi ...
Страница 30: ...056341 Rev AA NAVIGAT X Mk 2 Page 2 18 2 Operation ...
Страница 52: ...056341 Rev AA NAVIGAT X Mk 2 Page 5 8 5 Installation ...
Страница 66: ...056341 Rev AA NAVIGAT X Mk 2 Page 6 14 6 System Configuration ...
Страница 92: ...056341 Rev AA NAVIGAT X Mk 2 Page A 2 App A Setup Tables ...
Страница 94: ......
Страница 96: ......
Страница 98: ......
Страница 100: ...056341 Rev AA NAVIGAT X Mk 2 Page B 2 App B Drawings ...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ... ...
Страница 110: ......
Страница 111: ......