Figure 4-9.
Configuration Jumpers and Connectors.
The N-1000-III/IV panels
provide for either 485 multi-drop communication or 20 mA communication loops. These modes
are selected by changing jumper settings.
4-10: Connectors
Connector
Function
Battery Wires
Red and Black wires soldered to the circuit board with fast-on
connectors for the 12 volt backup battery
J1
Four pin connector for the AEP-3 (Revision A) Relay
Expansion Board(s)
J2
Eight pin connector for the AEP-3 (Revision B) Relay
Expansion Board(s)
Panel must be
earth grounded.
S-4 SUPPRESSION
REQUIRED ACROSS
EVERY ACTIVE RELAY
AND ELECTRICAL
DEVICE (CONNECT
WITHIN 18 INCHES).
Lock Solenoid
1
3
4
5
6
7
8
9
10
2
11
12
Jumpers 2, 3 & 4
Jumper 1
Jumper 10
Jumper 9
Jumper 6
Jumpers 5, 7, 8, and
11 are not used.
Battery Wires with
fast-on connectors
J2 AEP-3
Rev. B Connector
J1 AEP-3
Rev. A Connector