Chapter 2: Installation
3D SENSOR 2x50/2x70
Setting the IP Address for the Management Interface
In this section you set up the network interface that you will use later to administer
the 3D Sensor.
To configure the interface:
1.
Connect to the 3D Sensor in one of the following ways:
•
Connect a monitor and a keyboard to the 3D Sensor and set the
management interface to an IP address on the same subnet as the
administration system.
•
Create an alias on the administration system that is on the same subnet
as the default IP address of the management interface (192.168.45.45)
and then access the 3D Sensor remotely using SSH.
2.
Log in as root. The system requests a password.
3.
Enter
Nortel
as the password.
TIP!
Note that the password is case sensitive.
WARNING!
Nortel strongly recommends that you change this password
before installing the 3D Sensor in a production environment.
4.
To change the password, type
passwd
then enter the new password for root.
Be sure to document the new password.
5.
To determine the name of the management interface, enter the following
command:
grep MANAGEMENT /etc/sf/ims.conf
6.
To configure the management interface, enter the following command:
ifconfig eth# ipaddr netmask mask broadcast bcastaddr
where
eth#
is the result you received for the command in the previous step,
and
ipaddr
,
mask
, and
bcastaddr
are the values you want to use in your
network environment. For example:
ifconfig eth0 192.168.10.5 netmask 255.255.255.0
broadcast 192.168.10.255
7.
If the 3D Sensor is on a different subnet from the web browser, add a default
route as shown in the following command:
route add default gw gw_addr
where
gw_addr
is the IP address of the default gateway. For example:
route add default gw 192.168.10.1
8.
Continue with
“Performing the initial setup” on page 36
.