Module installation and connection

7

Use a Phillips screwdriver to tighten the two captive screws to
secure the module to the chassis.

Make sure that both screws are tight for proper module
operation.

Nortel Ethernet Routing Switch 8600

Installation — Modules

NN46205-304

02.02

Standard

16 June 2008

Copyright © 2008 Nortel Networks

.

Содержание Passport 8600 Series

Страница 1: ...Nortel Ethernet Routing Switch 8600 Installation Modules Release 5 0 Document Revision 02 02 www nortel com NN46205 304 312749 L Rev 02 ...

Страница 2: ...DITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks Velcro is a trademark of Velcro Industries B V PowerPC is a trademark of International Business Machines Corp All other trademarks are the property of their respective owners ...

Страница 3: ...4 Release 5 x module feature set 26 Ethernet Routing Switch 8600 modes 27 M mode configuration requirements 28 R mode configuration requirements 28 Chassis slots and modules 29 Module removal and switch behavior considerations 29 SAM and WSM modules 30 ATM modules 30 SF CPU modules 30 Interface module descriptions 30 8608GBE and 8608GBM modules 31 8608GTE and 8608GTM modules 33 8608SXE module 35 8...

Страница 4: ...ctions 82 Module installation and connection 85 Job aid avoiding ESD 87 Removing a filler panel 87 Installing a filler panel 88 Removing a module 89 Installing a module 93 Installing a PCMCIA card in the SF CPU module 97 Protecting PCMCIA card files 99 Installing the Enterprise enhanced CPU daughter card 100 Connecting a PC or terminal to the SF CPU or WSM 103 Connecting a modem to the SF CPU 104 ...

Страница 5: ...691 SF CPU Management port 141 8691 SF CPU Console port 142 8691 SF CPU Modem port 142 8692 SF CPU module 143 8692 SF CPU Management port 144 8692 SF CPU Console port 145 8692 SF CPU modem port 145 Port density for Ethernet Routing Switch 8600 modules 146 Translations of Safety Messages 151 Navigation 151 Class A electromagnetic interference caution statement 151 Electromagnetic interference cauti...

Страница 6: ...6 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 7: ...ational Electromagnetic Compliance EMC Statements of Compliance FCC Statement USA only This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Страница 8: ... 2004 108 EC Conformity is declared by the application of EN 55 022 Class A CISPR 22 CAUTION This device is a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users are required to take appropriate measures necessary to correct the interference at their own expense EN 55 024 Statement This is to certify that the Nortel 8000 Ser...

Страница 9: ...CCI Statement Japan Nippon only This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI for information technology equipment If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions BSMI Statement for 8010 8006 and 8003 Chassis Taiwan only This is a Cla...

Страница 10: ...teries are long life batteries and it is very possible that you will never need to replace them However should you need to replace them refer to the individual component manual for directions on replacement and disposal of the battery NOM Statement 8010 8006 and 8003 Chassis Mexico only The following information is provided on the devices described in this document in compliance with the safety re...

Страница 11: ...y 200 240 VAC 50 60 Hz 9 3 A maximum for each power supply Model 8004DC 48 60 VDC 29 23 A Model 8005DC 48 60 VDC 42 34 A Información NOM unicamente para México La información siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento en cumplimiento con los requisitos de la Norma Oficial Méxicana NOM Exportador Nortel Networks Inc 4655 Great America Parkway Santa ...

Страница 12: ...x por fuente de poder Model 8005AC 100 120 VCA 50 60 Hz 16 A max por fuente de poder 200 240 VCA 50 60 Hz 9 5 A max por fuente de poder Model 8005DI AC 100 120 VCA 50 60 Hz 16 A max por fuente de poder 200 240 VCA 50 60 Hz 9 3 A max por fuente de poder Model 8004DC 48 VCD 29 A Model 8005DC 48 VCD 42 A Denan Statement Japan Nippon only Nortel Ethernet Routing Switch 8600 Installation Modules NN4620...

Страница 13: ...t how to avoid discharge of static electricity and subsequent damage to Nortel products CAUTION ESD décharge électrostatique La mention ESD fournit des informations sur les moyens de prévenir une décharge électrostatique et d éviter d endommager les produits Nortel CAUTION ACHTUNG ESD ESD Hinweise bieten Information dazu wie man die Entladung von statischer Elektrizität und Folgeschäden an Nortel ...

Страница 14: ... mögliche Dienstunterbrechungen oder Schäden an Nortel Produkten verhindert CAUTION PRECAUCIÓN Los avisos de Precaución brindan información acerca de cómo evitar posibles interrupciones del servicio o el daño a los productos Nortel CAUTION CUIDADO Os avisos de cuidado oferecem informações sobre como evitar possíveis interrupções do serviço ou danos aos produtos da Nortel CAUTION ATTENZIONE Le indi...

Страница 15: ...danni alle persone durante l utilizzo dei prodotti Nortel Danger High Voltage Notice DANGER Danger High Voltage notices provide information about how to avoid a situation or condition that can cause serious personal injury or death from high voltage or electric shock DANGER La mention Danger Tension élevée fournit des informations sur les moyens de prévenir une situation ou une condition qui pourr...

Страница 16: ...otice DANGER Danger notices provide information about how to avoid a situation or condition that can cause serious personal injury or death DANGER La mention Danger fournit des informations sur les moyens de prévenir une situation ou une condition qui pourrait entraîner un risque de blessure grave ou mortelle DANGER GEFAHR Gefahrenhinweise stellen Informationen darüber bereit wie man Situationen o...

Страница 17: ...ericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 18: ...18 Regulatory Information and Safety Precautions Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 19: ...58 and Table 63 8634XGRS module specifications page 131 8648GBRS module page 61 and Table 65 8648GBRS module specifications page 132 8648GTRS module page 62 and Table 70 8648GTRS module specifications page 134 Other changes See the following sections for information about changes that are not feature related Modules and power information Information about SFP and XFP power consumption is added to ...

Страница 20: ...ot swapping procedures The following procedures are moved to Nortel Ethernet Routing Switch 8600 Upgrades Software Release 5 0 NN46205 400 Replacing a SF CPU module in a single CPU chassis Hot swapping the Master SF CPU module in a dual CPU chassis Hot swapping the Slave SF CPU module in a dual CPU chassis Hot swapping an I O module Document changes This document is reformatted to comply with the ...

Страница 21: ...8600 modules Navigation Ethernet Routing Switch 8600 module fundamentals page 23 Module installation and connection page 85 Technical specifications page 113 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 22: ...22 Introduction Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 23: ...ibed in this document see Nortel Ethernet Routing Switch 8600 Administration NN46205 600 Navigation Release 3 x module feature set page 24 Release 4 x module feature set page 24 Release 5 x module feature set page 26 Ethernet Routing Switch 8600 modes page 27 Chassis slots and modules page 29 Module removal and switch behavior considerations page 29 Interface module descriptions page 30 Nortel qua...

Страница 24: ...y allocated to each Gigabit Ethernet port or shared among the eight 10 100 ports Release 4 x module feature set Each Ethernet Routing Switch 8600 R module for Release 4 x consists of a Distributed Processing module DPM and a Port Interface Module PIM The PIM consists of various Media Access Controls MAC and Physical Layer Controls PHY and the physical interfaces for direct network connections A si...

Страница 25: ... port As part of the lookup process it can also determine and record the egress queue ID and pass it to the egress RSP2 Encapsulation is the most significant egress operation that the RSP2 performs To specify the egress queue the queuing and traffic shaping functions use encapsulation information from the egress RSP2 MAC and IP packet headers Quality of Service QoS markings The F2E egress ASIC sup...

Страница 26: ...can access pertinent information about the state of all other R modules in the system Among R modules the 8648GTR is potentially 2 4 1 oversubscribed on both lanes the 8630GBR the 8683XLR and the 8683XZR all operate at line rate Release 5 x module feature set Release 5 0 adds support for four new modules termed RS modules RS modules use a two or three lane forwarding module called the Distributed ...

Страница 27: ...e The 8612XLRS is potentially 4 1 oversubscribed on all lanes The 8634XGRS modules uses a three lane design based on RSP 2 6 architecture Potential 8634XGRS oversubscription is as follows Lane 1 RJ 45 and SFP 1 6 1 Lane 2 RJ 45 and SFP 1 6 1 Lane 3 XFP 2 1 The 8648GBRS modules use a three lane design based on RSP 2 6 architecture The 8648GBRS is potentially 1 6 1 oversubscribed on all lanes Ethern...

Страница 28: ...es the E modules are disabled This protects the system forwarding tables from lost entries M modules offer additional memory to support large routing tables such as those found in BGP implementations M mode or 128 000 records mode requires the 8691SF CPU module When enabled this mode allows M modules to use their full capabilities 128 000 records When disabled this mode allows the M modules to ope...

Страница 29: ...or replace a module in your chassis you can expect the following results If you replace a module with a different type of module the system discards the configuration of the old ports and adds the new ports to either the default VLAN or a null VLAN depending on the operating mode of the switch If you remove an interface module from an operating switch and replace it with the same type of module th...

Страница 30: ...dule from an operating switch and the module you insert has different MDAs you must reconfigure the module Nortel recommends that you save the original configuration in a file for future use SF CPU modules If you replace an 8691 SF CPU or 8692 SF CPU module all the other modules in the chassis reset and revert to their saved configuration settings If you did not save the configuration settings for...

Страница 31: ...E and 8648TXM modules page 43 8672ATME and 8672ATMM modules page 45 8683POSM module page 46 8630GBR module page 48 8648GTR module page 50 8683XLR module page 52 8683XZR module page 54 8612XLRS module page 56 8634XGRS module page 58 8648GBRS module page 61 8648GTRS module page 62 8608GBE and 8608GBM modules The 8608GBE and 8608GBM modules provide eight bays for GBICs Use GBICs to provide riser conn...

Страница 32: ... LEDs Table 1 8608GBE and 8608GBM module LEDs Type Label Color State Meaning Green Blinking The port is transmitting data Amber Steady A fault condition exists on the line or on the attached remote device TX Off The port has not detected a fault condition Green Steady The port is linked and enabled Green Blinking The port is receiving data Amber Steady The port has either no optical signal or no l...

Страница 33: ...igurations including Internet routing tables The 8608GBE module does not support R or M mode The 8608GBM module supports R and M mode 8608GTE and 8608GTM modules The 8608GTE and 8608GTM modules provide eight 1000BASE T CAT 5 Gigabit Ethernet ports that use 8 pin modular RJ 45 connectors Each port operates in 1000 Mbps 1 Gbps full duplex mode and supports IEEE 802 3 1998 Clause 28 Auto Negotiation ...

Страница 34: ...ting normally Amber Steady The module failed the power on self test Amber Blinking The module is inserted into the chassis and is running diagnostics Module Online Off The module power is off If the switch power is on the module is performing the power on self test and software initialization A module in this state is not yet functional The 8608GTE module supports up to 32 000 table entries in its...

Страница 35: ...lowing figure shows the 8608SXE module Figure 6 8608SXE module The optical transceiver provides transmission ranges as follows Up to 275 meters m using 62 5 micrometer µm multimode fiber cable Up to 550 m using 50 µm multimode fiber cable The following figure shows the location of the 8608SXE module LEDs Figure 7 8608SXE module LEDs The following table describes the 8608SXE module LEDs Nortel Ethe...

Страница 36: ...iled the power on self test Module Online Off The module power is off If the switch power is on the module is performing the power on self test and software initialization A module in this state is not yet functional The 8608SXE module supports up to 32 000 table entries in its forwarding engine The 8608SXE module does not support R or M mode 8616GTE module The 8616GTE module provides 16 1000BASE ...

Страница 37: ...appears to be steady Green Steady The module has completed the power on self test and software initialization and is operating normally Amber Steady The module failed the power on self test Amber Blinking The module is inserted into the chassis and it is running diagnostics Module Online Off The module power is off If the switch power is on the module is performing the power on self test and softw...

Страница 38: ...attachments or interswitch links The 8616SXE module supports standards based 1000 Mbps 1 Gbps full duplex operation only The following figure shows the 8616SXE module Figure 10 8616SXE module The optical transceivers provide transmission ranges as follows up to 275 m using 62 5 µm multimode fiber cable up to 550 m using 50 µm multimode fiber cable The following figure shows the location of the 861...

Страница 39: ... power is off If the switch power is on the module is performing the power on self test and software initialization A module in this state is not yet functional The 8616SXE module supports up to 32 000 table entries in its forwarding engine The 8616SXE module does not support R or M mode When you use an 8616 module with Auto Negotiation enabled set the re autoneg flag for proper interoperability S...

Страница 40: ...fiber cable The following figure shows the location of the LEDs Figure 13 8624FXE module LEDs The following table describes the 8624FXE module LEDs Table 6 8624FXE module LEDs Type Label Color State Meaning Green Steady The port is connected and the link is operational Green Blinking Data is passing through the port Amber Steady A fault condition exists at the far end of the connection Port Link A...

Страница 41: ...00 table entries in its forwarding engine The 8624FXE module does not support R or M mode 8632TXE and 8632TXM modules The 8632TXE and 8632TXM modules provide 32 autonegotiating 10BASE T 100BASE TX ports that use 8 pin modular RJ 45 connectors Ports operate at either 10 Mbps or 100 Mbps up to distances of 100 m with CAT 3 or better unshielded twisted pair UTP cable The following figure shows the 86...

Страница 42: ...Meaning Green Steady The module completed the power on self test and software initialization and is operating normally Amber Steady The module failed the power on self test Module Online Off The module power is off If the switch power is on the module is performing its power on self test and software initialization A module in this state is not yet functional Green Steady The port is operating at ...

Страница 43: ...ne The 8632TXM module is an M module and supports up to 128 000 table entries in its forwarding engine which supports large layer 2 and layer 3 configurations including Internet routing tables The 8632TXE module does not support R or M mode The 8632TXM module supports R and M mode 8648TXE and 8648TXM modules The 8648TXE and 8648TXM modules provide 48 autonegotiating 10BASE T 100BASE TX ports that ...

Страница 44: ...8 8648TXE and 8648TXM module LEDs Type Label Color State Meaning Green Steady The port is operating at 100 Mbps 10 100 Off The port is operating at 10 Mbps Green Steady The port is connected and the link is operational Green Blinking Data is passing through the port Port Link Activity Off The port is disabled or has no link Green Steady The module has completed the power on self test and software ...

Страница 45: ...nterface flexibility and ATM network transmission that supports RFC 1483 routed and bridged permanent virtual connections PVC The 8672ATME and 8672ATMM modules support Synchronous Optical Network SONET and Synchronous Digital Hierarchy SDH frame structures for data The following figure shows the ATM module Figure 18 8672ATME or 8672ATMM module with an OC 12c or STM 4 MDA These modules require at l...

Страница 46: ...s offline and not receiving power For a description of how to configure the 8672ATME and 8672ATMM modules see Nortel Ethernet Routing Switch 8600 Configuration 8672ATME and 8672ATMM Modules NN46205 511 The 8672ATME module supports up to 32 000 table entries in its forwarding engine The 8672ATMM module is an M module and supports up to 128 000 table entries in its forwarding engine which supports l...

Страница 47: ...e 8683POSM module has an Online LED that indicates the overall status for the module The following table describes the Online LED Table 10 8683POSM module LED Color State Meaning Green The module is receiving power and is ready to receive and transmit traffic Amber The module is initializing and performing diagnostic self tests Off The module is offline and is not receiving power For information a...

Страница 48: ...module is completely initialized you may have to upgrade the FPGA firmware image on the module to PIM 769 or later For upgrade instructions see Nortel Ethernet Routing Switch 8600 Upgrades Software Release 5 0 NN46205 400 The 8630GBR module is not supported in the 8003 chassis with Release 4 1 or later When a copper GBIC is present in an 8630GBR module port with Auto Negotiation disabled the port ...

Страница 49: ...eady The port is linked and is enabled Green Blinking 1 second on 1 second off The port is disabled Green Flashing The port is receiving data The LED flash rate indicates the level of activity on the link Amber Flashing Data error Port RX Off The port is enabled but has no link Green Steady The module is online and is operating normally Amber Steady The module failed its power on self test Amber B...

Страница 50: ...shows the 8648GTR Figure 22 8648GTR module The 8648GTR module is not supported in the 8003 chassis with Release 4 1 or later On the 8648GTR module ports operating at 100 Mbps support a maximum frame size of 9188 bytes Ports operating at 10 and 1000 Mbps support 9600 byte frames The 8648GTR module ports supports the IEEE 802 3 1998 Clause 28 Auto Negotiation standard Each port can operate in full o...

Страница 51: ...reen Steady The port is operating at 1000 Mbps Amber Steady The port is operating at 100 Mbps 10 100 1000 no label Off The port is operating at 10 Mbps Amber Blinking An error is detected Green Steady The port is connected and the link is operational Green Blinking Data is passing through the port The blink rate indicates the level of link activity Amber Steady The port is administratively disable...

Страница 52: ...000 IP routes 64 000 MAC records Release 4 1 and earlier 16 000 in R mode Release 5 0 and later 32 000 in R mode The 8648GTR module supports R and M mode The 8648GTR module supports prioritization of control MAC addresses For more information see Nortel Ethernet Routing Switch 8600 Configuration Ethernet Modules NN46205 503 8683XLR module The 8683XLR module provides three bays for 10 Gigabit Ether...

Страница 53: ...le due to cooling limitations on the 8683XLR and XZR modules when using standard fan trays Nortel further recommends that you install the XFP only in Port 1 You can install a 10GBASE SR LR LW or ER EW in one or both of the remaining ports There are no XFP limitations for this module in any slot when using the new cooling modules for the 8010 and 8006 chassis The following figure shows the location...

Страница 54: ...ower to the module If the switch power is on the module is performing the power on self test and software initialization A module in this state is not yet functional For a description of how to configure the 8683XLR module see Nortel Ethernet Routing Switch 8600 Configuration Ethernet Modules NN46205 503 The Ethernet Routing Switch 8600 8683XLR module is an R module and supports 256 000 IP routes ...

Страница 55: ...using standard fan trays Nortel further recommends that you install the XFP only in Port 1 You can install a 10GBASE SR LR LW or ER EW in one or both of the remaining ports There are no XFP limitations for this module in any slot when using the new cooling modules for the 8010 and 8006 chassis The 8683XZR module supports up to three XFP transceivers For a list of Nortel qualified XFPs for use in t...

Страница 56: ...isabled Module Online Off The module power is off If the switch power is on the module is performing the power on self test and software initialization A module in this state is not yet functional The 8683XZR module supports R and M mode 8612XLRS module The 8612XLRS module is a 12 port XFP baseboard This module supports twelve 10 Gbps ports four for each lane All RS modules require the high speed ...

Страница 57: ...mber label The following table describes the 8612XLRS module LEDs Table 15 8612XLRS module LEDs Type Label Color State Meaning Green Steady The port is connected and linked but no data flow Green Blinking The port is transmitting or receiving data The blink rate indicates the level of link activity Amber Blinking The port detects a Line or Remote fault Amber Steady The port is administratively dis...

Страница 58: ... support for a variety of technologies interfaces and feature sets and provide 10 Gbps port rates The 8634XGRS is a 34 port combination 10 Gbps and 1 Gbps interface module based on the Route Switch Processor RSP The module has 4 RJ 45 and 12 SFP ports in Lane 1 4 RJ 45 and 12 SFP ports in Lane 2 and 2 XFP ports in Lane 3 The XFP ports support IEEE 10 Gbps LAN PHY The following figure shows the 863...

Страница 59: ...ration Ethernet Modules NN46205 503 The following figure shows the LED locations Figure 31 8634XGRS module LEDs The following tables describe the 8634XGRS module LEDs Table 16 8634XGRS module LEDs Type Label Color State Meaning Green Steady The module has completed the power on self test and software initialization and is operating normally Amber Steady The module is booting Amber Blinking The mod...

Страница 60: ...is transmitting or receiving data The blink rate indicates the level of link activity Green Slow Blinking The port is administratively disabled Port Port number Off The port is connected but not linked Table 19 8634XGRS XFP port LEDS Type Label Color State Meaning Green Steady The port is connected and linked but no data flow Green Blinking The port is transmitting or receiving data The blink rate...

Страница 61: ...ort jumbo frames RS modules are not compatible with the 8001AC and 8002DC power supplies or the 8691 SF CPU modules You must use the 8692 SF CPU in chassis that contain RS modules RS modules interoperate with R modules For a list of Nortel qualified SFPs see Nortel qualified SFPs XFPs and GBICs page 64 The following figure shows the LED locations Figure 33 8648GBRS module LED locations The followi...

Страница 62: ...s off The Ethernet Routing Switch 8600 8648GBRS is an R series module and supports 256 000 IP routes 64 000 MAC records Release 4 1 and earlier 16 000 in R mode Release 5 0 and later 32 000 in R mode 8648GTRS module The 8648GTRS module is a 48 port RJ 45 10BASE T 100BASE TX 1000BASE T module The module supports IEEE 802 3 standards including Auto Negotiation The 8648GTRS module supports Custom Aut...

Страница 63: ...re 35 8648GTRS module LEDs The following table describes the 8648GTRS module LEDs Table 21 8648GTRS module LEDs Type Label Color State Meaning Green Steady The port is operating at 1000 Mbps Amber Steady The port is operating at 100 Mbps 10 100 1000 no label Off The port is operating at 10 Mbps Green blinking 1 1 flash 1 2 on 1 2 off The port is transmitting or receiving data Amber Steady The port...

Страница 64: ...g table for use in Ethernet Routing Switch 8600 interface modules Only GBICs qualified by Nortel are supported for use in Ethernet Routing Switch 8600 modules GBICs not qualified by Nortel can operate within the module but are not tested for power draw electromagnetic interference or interoperability Table 22 Nortel qualified GBICs GBIC order number Description AA1419041 E5 1000BASE T RJ 45 up to ...

Страница 65: ...m AA1419048 E6 1000BASE SX LC connector 850 nm DDI up to 275 or 550 m AA1419015 E5 1000BASE LX LC connector 1310 nm up to 10 km AA1419049 E6 1000BASE LX LC connector 1310 nm DDI up to 10 km AA1419069 E6 and AA1419070 E6 1000BASE BX LC connector 1310 and 1490 nm up to 10 km AA1419025 E5 to AA1419032 E5 1000BASE XD LC connector CWDM 1470 to 1610 nm up to 40 km AA1419050 E6 1000BASE XD LC connector 1...

Страница 66: ...onnectors 1310 nm DDI up to 10 km AA1403003 E5 10GBASE ER EW LC connectors 1550 nm DDI up to 40 km AA1403006 E5 10GBASE ZR ZW LC connectors 1550 nm DDI up to 80 km AA1403007 E6 10GBASE LRM LC connectors 1310 nm DDI up to 220 m SFPs XFPs R and RS modules and power consumption The power specifications for R and RS modules see Technical specifications page 113 show the power for the module with slots...

Страница 67: ...FPs Device Power consumption 1000BASE SX SFP 0 85 W 1000BASE LX 1000BASE BX 1000BASE XD and 1000BASE ZX CWDM SFPs 1 0 W 1000BASE EX 1000BASE XD and 1000BASE ZX DWDM SFPs 1 25 W 10GBASE SR XFP 2 0 W 10GBASE LR 10GBASE LRM 10GBASE ER XFPs 3 5 W 10GBASE ZR and DWDM XFPs 4 5 W SF CPU modules The following sections describe the Switch Fabric Central Processing Unit SF CPU modules 8691 SF CPU module The...

Страница 68: ... 8600 Upgrades Software Release 5 0 NN46205 400 The 8691 SF CPU 256 DS1404090 is functionally identical to the 8691 SF CPU except that it has 256 MB of SDRAM installed You can identify the 8691 SF CPU 256 by the front panel model number label in the upper right corner as 8691SF 256 The 8691 SF CPU module contains 16 MB of onboard flash memory used to store the image file and 2 MB of boot memory RO...

Страница 69: ... the 8691 SF CPU module LEDs Figure 37 8691 SF CPU module LEDs The Switch LEDs and the CPU LEDs indicate card activity The Switch bar graph increases as the switch fabric utilization increases The CPU bar graph increases when the CPU is performs tasks such as learning media access control MAC addresses updating routing tables or interacting with the device management station The following table de...

Страница 70: ...Ds 36 7 LEDs 84 CPU Utilization 8 LEDs Green 4 LEDs 48 8 LEDs 100 Green Steady The specified power supply is operating normally Amber Steady The specified power supply failed Power Supply 1 2 3 Off A power supply is not present in the specified bay or the power supply in the specified bay is not turned on Green Steady The specified fan is operating normally Amber Steady The specified fan is presen...

Страница 71: ...port has its own IP address but does not switch traffic to other ports in the chassis This port can be used only as a management port This port provides out of band management for the 8691 SF CPU module 8691 SF CPU DCE DTE switch The DCE DTE switch changes the pin assignments on the Console port You can designate the connector as either DTE or DCE For information about pin assignments for the Cons...

Страница 72: ...outing Switch 8600 Series with a write protected memory card Make a copy of your configuration on another memory card write protect that card and store it in a safe place If you do not have a second memory card you can copy your configuration to a TFTP or FTP server ATTENTION The 8691 SF CPU module provides event logging capability to internal RAM and to a removable PCMCIA flash memory card but no...

Страница 73: ...see Installing the Enterprise enhanced CPU daughter card page 100 The Flash memory consists of two volumes Volume 0 has a capacity of 16 MB and Volume 1 has a capacity of 64 MB You can use either volume to store multiple file types either Volume 0 or Volume 1 By default the system can only use 16 MB on Volume 0 If you want to use 64 MB on Volume 1 see Ethernet Routing Switch 8600 Upgrades Software...

Страница 74: ... module with any release below Ethernet Routing Switch 8600 Release 3 5 6 this can damage the module CAUTION Risk of data loss Before you insert an 8692 SF CPU in a Secondary SF CPU slot make sure that the Master SF CPU runs the required software release 8692 SF CPU LEDs The following figure shows the location of the 8692 SF CPU module LEDs Figure 39 8692 SF CPU module LEDs The Switch LEDs and the...

Страница 75: ...bps Switch Utilization 8 LEDs Green The number of lit LEDs indicates the utilization level full duplex operation of the switch fabric as follows 1 LED 4 0 Gbps to 34 Gbps 2 LEDs 34 Gbps to 68 Gbps 3 LEDs 68 Gbps to 102 Gbps 4 LEDs 102 Gbps to 136 Gbps 5 LEDs 136 Gbps to 170 Gbps 6 LEDs 170 Gbps to 204 Gbps 7 LEDs 204 Gbps to 238 Gbps 8 LEDs 238 Gbps to 256 Gbps The number of lit LEDs indicates the...

Страница 76: ...s in a fault state Master Off The CPU subsystem on the module is up and in Standby mode Green Steady The switch fabric portion of the module is online and is load sharing Amber Steady The switch fabric portion of the module failed diagnostics Online Off The switch fabric portion of the module is offline 8692 SF CPU Ethernet management port The Ethernet management port on the 8692 SF CPU module is ...

Страница 77: ...hes or store multiple configurations for a single switch ATTENTION For Release 5 0 and later Nortel recommends that you use a PCMCIA card of not less than 256 MB storage capacity The part number of the 3 3 V 256 MB PCMCIA card is DS1411022 Nortel ships each memory card with its read write protect switch in the unprotected position After you successfully load the configuration file and save your co...

Страница 78: ...iness transactions and confidential data by off loading Secure Sockets Layer SSL processing from local servers without imposing delays on other traffic in the same data path The following figure shows the SAM Figure 40 8661 SAM You cannot install the 8661 SSL Acceleration Module in an 8003 chassis The 8661 SAM consists of two parts An SSL Input Output Module I O A Backplane Fabric Module BFM that ...

Страница 79: ...st one Web Switching Module You cannot install the 8661 SAM in an 8003 chassis For information about how to perform 8661 SAM system configuration and maintenance see Nortel Ethernet Routing Switch 8600 Configuration 8661 SSL Accelerator with the Web Switching Module NN46205 514 SAM LEDs The 8661 SAM includes an Online LED that indicates overall status for the module and an Active LED to indicate t...

Страница 80: ...ance port The 8661 SAM maintenance port is a DIN 8 connector that includes the same physical characteristics as the WSM maintenance port However the 8661 SAM maintenance port is not supported in the initial SAM 8661 release 3 3 1 Web Switching Module The Web Switching Module WSM and Ethernet Routing Switch 8600 Series I O modules provide a complete Layer 2 through layer 7 switching solution You ca...

Страница 81: ...st disable M Mode WSM and slots The slots in the 8010 8006 and 8003 chassis are numbered from the top down starting with slot 1 The slots in the 8010co are numbered from left to right starting with slot 1 In the 8010co 8010 and 8006 chassis slots 5 and 6 are reserved for switch fabric modules In the 8003 chassis slot 3 is reserved for switch fabric module You can install any of the supported Ether...

Страница 82: ...ne Green steady The module completed the power on self test and software initialization and is operating normally Automatic selection of redundant connections The WSM supports dual media configuration on the front facing ports 1 to 4 The module automatically boots up and fails between the range 10 100 Mbps and 1000 Mbps port pairs The following list describes the order of precedence If both the 10...

Страница 83: ...s link is active and the Gigabit Ethernet link becomes viable because of a newly created connection or repaired link the 10 100 Mbps link remains active until one of the following actions occur The 10 100 Mbps link fails or you remove it You force the Gigabit Ethernet to become the active link from any management interface Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 ...

Страница 84: ...84 Ethernet Routing Switch 8600 module fundamentals Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 85: ...tions Module installation and connection procedures This task flow shows you the sequence of procedures you perform to install and connect modules To link to any task go to Module installation and connection procedure navigation page 86 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 86: ... filler panel page 87 Installing a filler panel page 88 Removing a module page 89 Installing a module page 93 Installing a PCMCIA card in the SF CPU module page 97 Protecting PCMCIA card files page 99 Installing the Enterprise enhanced CPU daughter card page 100 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 87: ...ischarge leash or wrist strap to free yourself of static before you touch a module An antistatic wrist strap is shipped with the 8010co chassis You can also free yourself of static by touching the metal chassis before you handle the module When you handle modules do not touch components on the circuit boards always handle module by their edges Store unused modules in protective packaging Removing ...

Страница 88: ...nel or a module installed in a slot End Installing a filler panel If you plan to remove a module from the chassis without immediately replacing it you must install a filler panel in the slot To maintain proper airflow and cooling always cover unused module slots and power supply bays with filler panels Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008...

Страница 89: ...fore you remove an 8691 or 8692 SF CPU module back up your configuration If the chassis includes only one SF CPU module and you remove it the switch does not operate Ensure that traffic is not traversing the module Disable the module before you remove it For further instructions see Nortel Ethernet Routing Switch 8600 Configuration Ethernet Modules NN46205 503 WARNING Risk of eye injury by laser F...

Страница 90: ...e electromagnetic interference to other equipment in the area Improper equipment cooling can also result Procedure steps Step Action 1 Disconnect any cables attached to the ports on the module 2 Use a Phillips screwdriver to loosen the two captive screws that secure the module to the chassis Throughout the remainder of this procedure the first figure shows the 8003 8006 and 8010 chassis the second...

Страница 91: ...e the insert or extract levers to eject the module from the chassis as shown in the following figures Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 92: ...tion and connection 4 Slide the module out of the chassis as shown in the following figures Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 93: ...talling a module takes three to five minutes Prerequisites If you insert a SAM into a chassis where another SAM resides make sure that the first module is fully initialized before you insert the second CAUTION Risk of equipment damage Electrostatic discharge can damage hardware Follow proper ESD elimination procedures Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Stand...

Страница 94: ...vers are extended away from the front of the module 4 Slide the module into the slot using the slot module guides as shown in the following figures Throughout the remainder of this procedure the first figure shows the 8003 8006 and 8010 chassis the second figure shows the 8010co chassis Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 ...

Страница 95: ...ntil its connector panel touches the chassis back panel 6 Rotate the insert and extract levers to seat the module backplane connectors Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 96: ...er to tighten the two captive screws to secure the module to the chassis Make sure that both screws are tight for proper module operation Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 97: ...d later Nortel recommends that you use a PCMCIA card of not less than 256 MB storage capacity Procedure steps Step Action 1 For the 8010co chassis position the card with the label facing to the left and the insert arrow pointing toward the card receptacle Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 98: ...ptacle 2 Insert the card into the card receptacle 3 Gently push in the card until it fits snugly in place 4 To remove a PCMCIA card in the CLI or NNCLI first issue the stop command pcmcia stop 5 Press the eject button and remove the card Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 99: ...rd so that important files are not overwritten or remove the protection to write files to the card Procedure steps Step Action 1 Remove the memory card from the SF CPU module Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 100: ...essing from the CPU to the daughter card and to enable use of all Ethernet Routing Switch 8600 features Installing a SuperMezz takes appriximately 10 minutes ATTENTION If you have a system with two Ethernet Routing Switch 8692SF CPU modules you must install the daughter card on each of the modules Prerequisites The 8692 SF CPU is removed from the Ethernet Routing Switch 8600 using proper removal p...

Страница 101: ... from the factory with all required hardware Ensure your shipment includes all of the items CPU daughter card Hex key 2 socket head screws 2 56x0 625 2 socket head screws 2 56x0 188 2 Pick up the CPU daughter card 3 Align the CPU daughter card connectors with the connectors on the 8692 SF CPU Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright...

Страница 102: ...r socket head screws Install the 2 56 x 625 screws first See the following figure for correct screw placement After you place the screw in the hole insert the hex key through the mezzanine card hole to secure the screw Do not overtighten the screws It is normal for a slight space to be visible between the CPU daughter card and the CPU standoffs Nortel Ethernet Routing Switch 8600 Installation Modu...

Страница 103: ...ting Switch 8600 connect a PC or a VT 100 terminal to the console port on the 8691 SF CPU or 8692 SF CPU module The port labeled Maint provides direct terminal access to the WSM When you connect to the WSM using the maintenance port you have direct access to the Web OS CLI You do not see the top level Ethernet Routing Switch 8600 CLI For information about the Web OS CLI see Web OS Switch Software ...

Страница 104: ...modem to the SF CPU Use an AT or Hayes compatible modem and serial cable to provide remote dial in access to the CLI Procedure steps Step Action 1 Turn on and configure the modem using the parameters in the following table See the modem documentation for instructions Setting Value Clear to send CTS signal On Data terminal ready DTR signal Modem can only connect if the DTR signal is present If the ...

Страница 105: ...cting a network management station to the SF CPU Use the management port to connect the switch to a network management station for out of band management using a Web browser or Device Manager Procedure steps Step Action 1 Connect an Ethernet cable to the network management station For 10 Mbps connections you can use Category 3 4 or 5 copper unshielded twisted pair Ethernet cable Use only Category ...

Страница 106: ...el and bundle the cables for each module together Procedure steps Step Action 1 Connect the appropriate cable to the module 2 Route the cable up to the appropriate cable management bracket and channel as shown in the following figures The first figure shows the 8010 8006 8003 chassis The second shows the 8010co chassis Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Stan...

Страница 107: ...f cable 5 Label the unconnected end of the cable with the node identifier from site records and the shelf cage slot and port number 6 When all the transmitting cables from the same module are connected to the termination panel use velcro straps or sheet fiber wrapped around the cables to manage them 7 Use scissors to cut a section of the sheet fiber wide enough to wrap around the cables Nortel Eth...

Страница 108: ...rough cables to connect these ports to MDI connections such as workstations or servers Use crossover cables to connect these ports to other MDI X connections such as hubs or other switches The following table lists the cable requirements for the Ethernet Routing Switch 8600 modules For GBIC SFP and XFP cable types and cable lengths see Nortel Ethernet Routing Switch 8600 Installation SFP XFP OADM ...

Страница 109: ... 722 ft 220 m 160 MHz km bandwidth 902 ft 275 m 200 MHz km bandwidth 8608SXE 1000BASE SX Duplex SC 50 µm MMF 1640 ft 500 m 400 MHz km bandwidth 1804 ft 550 m 400 MHz km bandwidth 8616GTE 1000BASE T RJ 45 EIA CAT 5 or better UTP STP straight through cable Cables must use all four pairs 7 ft 2 1 m 328 ft 100 m 62 5 µm MMF 722 ft 220 m 160 MHz km bandwidth 902 ft 275 m 200 MHz km bandwidth 8616SXE 10...

Страница 110: ... Mbps operation EIA CAT 5 UTP required for 100 Mbps operation 328 ft 100 m MT RJ 9 µm single mode fiber SMF 9 3 mi 15 km 8672ATME OC 3 or 8672ATMM OC 3 MT RJ 62 5 µm MMF 1 24 mi 2 km Duplex SC 9 µm SMF 9 3 mi 15 km 8672ATME OC 12 or 8672ATMM OC 12 Duplex SC 62 5 µm MMF 1640 ft 500 m 8672ATME DS 3 or 8672ATMM DS 3 BNC 75 ohm coaxial cable 450 ft 137 m MT RJ 9 µm SMF 9 3 mi 15 km 8683POSM OC 3 MT RJ...

Страница 111: ...m RJ 45 Ethernet Management port EIA CAT 3 4 or 5 UTP for 10 Mbps operation EIA CAT 5 UTP required for 100 Mbps operation 8691 SF CPU DB 9 Serial port RS 232 328 ft 100 m RJ 45 Ethernet Management port EIA CAT 3 4 or 5 UTP for 10 Mbps operation EIA CAT 5 UTP required for 100 Mbps operation 8692 SF CPU DB 9 Serial port RS 232 328 ft 100 m 1000BASE SX Gigabit Ethernet po rts Duplex SC 62 5 µm MMF 72...

Страница 112: ...600 cont d Module Connector Recommended cable type Minimum cable length Maximum cable length Maintenance port DB 9 to DIN 8 RS 232 SAM Maintenance port DB 9 to DIN 8 RS 232 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 113: ...GTE and 8608GTM modules page 117 8608SXE module page 119 8616GTE module page 120 8616SXE module page 121 8624FXE module page 123 8632TXE and 8632TXM modules page 124 8648TXE and 8648TXM modules page 125 8672ATME and 8672ATMM modules page 126 8683POSM module page 128 8612XLRS module page 129 8630GBR module page 130 8634XGRS module page 131 8648GBRS module page 132 8648GTR module page 132 8648GTRS m...

Страница 114: ... 1998 Clause 21 100BASE TX ANSI IEEE Std 802 3 1998 Media Access Control MAC Bridges IEEE 802 1Q Virtual Bridged Local Area Networks IEEE Std 802 3 1998 Clause 34 42 IEEE 802 3 1998 Clause 31 MAC Control IEEE Std 802 3ab IEEE Std 802 3ae Data rate and encoding 10 Mbps Manchester encoding 100 Mbps 4B 5B encoding 1000 Mbps 8B 10B encoding 10 Gbps 64 66B encoding The following table provides module e...

Страница 115: ...atency Minimum 10 microseconds Address database size Address table size E modules 32 000 table entries for each system M modules 128 000 table entries for each system when configured for M mode Some entries are reserved for system use R series modules 256 000 table entries for each system when configured for R mode Addressing 48 bit MAC address 32 bit IPv4 address 128 bit IPv6 address R series mod...

Страница 116: ...N 55022 1998 Class A EN 61000 3 2 A14 EN 61000 3 3 Global CISPR 22 1997 Class A CE Mark Electromagnetic susceptibility EN55024 1998 CISPR 24 1997 The following table describes safety agency approvals Table 35 Safety agency approvals Safety agency approvals US UL60950 Canada CSA 22 2 No 60950 Australia New Zealand AS NZS 3260 Mexico NOM 019 SCFI 1998 The Gigabit Ethernet transceivers installed in t...

Страница 117: ...rs hr Connector type GBIC SC fiber or RJ 45 copper 8608GTE and 8608GTM modules The following table provides specifications for the 8608GTE and M modules Table 37 8608GTX module specifications Physical specifications Height 1 5 inches in 3 8 centimeters cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 0 pounds lb 3 6 kilograms kg Electrical specifications Input power 138 1 Watts W maximum Se...

Страница 118: ...s Table 38 8608GTE power specifications Specification Value 3 3 V power W 73 3 12 V power W 64 8 Total power W 138 1 Port connectors The ports on the 8608GTE and 8608GTM modules are RJ 45 ports wired as shown in the following table Table 39 Pin assignments 8608GTE and 8608GTM module port Connector Pin number Signal 1 Bidirectional Data A BI_DA 2 Bidirectional Data A BI_DA 3 Bidirectional Data B BI...

Страница 119: ...ng table provides power specifications Table 41 8608SXE power specifications Specification Value 3 3 V power W 82 8 12 V power W 30 0 Total power W 112 8 The following table provides cable specifications Table 42 8608SXE cable specifications Cable specifications Type 62 5 µm or 50 µm multimode fiber optic cable Maximum distance 62 5 µm multimode fiber optic cable 722 ft 220 m 160 MHz km bandwidth ...

Страница 120: ...characteristics Minimum receiver sensitivity 17 dBm Maximum input power 0 dBm 8616GTE module The following table provides specifications for the 8616GTE modules Table 44 8616GTE specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 0 lb 3 6 kg Electrical specifications Input power 129 2 W maximum Thermal rating 440 6 Btu hr maximum Nortel ...

Страница 121: ...ecification Value 3 3 V power W 64 4 12 V power W 64 8 Total power W 129 2 The ports on the 8616GTE module are RJ 45 ports wired as shown in the following table Table 46 Pin assignments 8616GTE module port Connector Pin number Signal 1 Bidirectional Data A BI_DA 2 Bidirectional Data A BI_DA 3 Bidirectional Data B BI_DB 4 Bidirectional Data C BI_DC 5 Bidirectional Data C BI_DC 6 Bidirectional Data ...

Страница 122: ...ations Specification Value 3 3 V power W 82 8 12 V power W 64 8 Total power W 147 6 The following table provides cable specifications Table 49 8616SXE cable specifications Cable specifications Type 62 5 µm or 50 µm multimode fiber optic cable Maximum distance 62 5 µm multimode fiber optic cable 722 ft 220 m 160 MHz km bandwidth 902 ft 275 m 200 MHz km bandwidth 50 µm multimode fiber optic cable 16...

Страница 123: ...ations for the 8624FXE modules Table 51 8624FXE specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 7 6 lb 3 4 kg Electrical specifications Input power 84 8 W maximum Thermal rating 289 2 Btu hr maximum MTBF rating 320 972 hr Connector type MT RJ Cable specifications Type 62 5 µm multimode fiber optic cable Distance 6562 ft 2 km for full d...

Страница 124: ...ns Specification Value 3 3 V power W 64 4 12 V power W 20 4 Total power W 84 8 8632TXE and 8632TXM modules The following table provides specifications for the 8632TXE and M modules Table 53 8632TXE and 8632TXM module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 9 lb 4 kg Electrical specifications Input power 100 W maximum Thermal ra...

Страница 125: ...des specifications for the 8648TXE and M modules Table 54 8648TXE and TXM module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 0 lb 3 6 kg Electrical specifications Input power 76 W maximum Thermal rating 261 Btu hr maximum MTBF rating 244 708 hr Connector type RJ 45 connector wired as MDI X see Cable specifications Type Category 3...

Страница 126: ...6 ATM module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 0 lb 3 6 kg Electrical specifications Input power OC 3c MDA 40 W maximum OC 12c MDA 40 W maximum DS 3 MDA 40 W maximum Thermal rating OC 3c MDA 138 Btu hr maximum OC 12c MDA 138 Btu hr maximum DS 3 MDA 138 Btu hr maximum MTBF rating 222 103 hr Connector type OC 3c MDA MT RJ...

Страница 127: ...pecifications Wavelength OC 3c MDA SMF 1274 to 1356 nm OC 3c MDA MMF 1274 to 1356 nm OC 12c MDA SMF 1274 to 1356 nm OC 12c MDA MMF 1260 to 1360 nm Average transmit output power OC 3c and OC 12c MDAs SMF 8 to 15 dBm OC 3c and OC 12c MDAs MMF 14 to 29 dBm Average receiver sensitivity OC 3c MDA SMF 14 to 28 dBm OC 3c MDA MMF 14 to 29 dBm OC 12c MDA SMF 7 to 18 dBm OC 12c MDA MMF 14 to 28 dBm The foll...

Страница 128: ...47 0 cm Weight Electrical specifications Input power OC 3c MDA 70 W maximum OC 12c MDA 90 W maximum Thermal rating OC 3c MDA 241 Btu hr maximum OC 12c MDA 310 Btu hr maximum MTBF rating 255 693 hr Connector types OC 3c MDA MT RJ OC 12c MDA Duplex SC Cable specifications Type Multimode or single mode fiber optic cable Maximum distance Multimode fiber optic cable 1 24 mi 2 km for OC 3c connection 16...

Страница 129: ...transmit output power OC 3c and OC 12c MDAs SMF 8 to 15 dBm OC 3c and OC 12c MDAs MMF 14 to 29 dBm Average receiver sensitivity OC 3c MDA SMF 14 to 28 dBm OC 3c MDA MMF 14 to 29 dBm OC 12c MDA SMF 7 to 18 dBm OC 12c MDA MMF 14 to 28 dBm 8612XLRS module The following table describes the 8612XLRS module specifications Table 59 8612XLRS module specifications Physical specifications Height 1 5 in 3 8 ...

Страница 130: ...or power additions for middle and long range XFPs see SFPs XFPs R and RS modules and power consumption page 66 Table 60 8612XLRS power specifications including short range XFP power Specification Value 3 3 V power W 80 3 12 V power W 177 6 Total power W 257 9 8630GBR module The following table describes the 8630GBR module specifications Table 61 8630GBR module specifications Physical specification...

Страница 131: ...escribes the 8634XGRS module specifications Table 63 8634XGRS module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 10 lb 4 54 kg Electrical specifications Input power 259 1 W maximum includes XFPs and SFPs See the following table Thermal rating 883 5 Btu hr maximum MTBF rating 369 190 hr Connector type LC Performance specifications A...

Страница 132: ...able Thermal rating 926 2 Btu hr maximum MTBF rating 367 634 hr Connector type LC Performance specifications Aggregate throughput 8 5 Gbps The following table provides power data for an 8648GBRS module filled with short range SFPs For power additions for middle and long range SFPs see SFPs XFPs R and RS modules and power consumption page 66 Table 66 8648GBRS power specifications including short ra...

Страница 133: ...n Category 5 or better UTP cable for 100 Mbps and 1000 Mbps operation Cables must use all four pairs Wiring configuration and performance are defined by EIA TIA Standard 568 and IEEE Standard 802 3 2000 edition Maximum distance 328 ft 100 m The following table provides power specifications Table 68 8648GTR power specifications Specification Value 3 3 V power W 73 9 12 V power W 90 Total power W 16...

Страница 134: ...module The following table lists specifications for the 8648GTRS module Table 70 8648GTRS module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 10 lb 4 54 kg Electrical specifications Input power 208 4 W maximum See the following table Thermal rating 710 6 Btu hr maximum MTBF rating 388 833 hr Connector type RJ 45 see 8648GTR port con...

Страница 135: ...Maximum distance 328 ft 100 m The following table provides power specifications Table 71 8648GTRS power specifications Specification Value 3 3 V power W 71 6 12 V power W 136 8 Total power W 208 4 8683XLR module The following table describes the 8683XLR module specifications Table 72 8683XLR module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0...

Страница 136: ...Table 73 8683XLR power specifications including short range XFPs Specification Value 3 3 V power W 77 9 12 V power W 90 0 Total power W 167 9 8683XZR module The following table describes the 8683XZR module specifications Table 74 8683XZR module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 0 lb 3 6 kg Electrical specifications Inpu...

Страница 137: ... 0 Total power W 170 9 8660 SDM Some 8660 Services Delivery Module specifications are found in the following table for more details see Nortel Ethernet Routing Switch 8600 Installation 8660 Service Delivery Module NN46205 301 Table 76 8660 SDM module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 11 0 lb 5 0 kg Electrical specificatio...

Страница 138: ... Depth 18 5 in 47 0 cm Weight 14 0 lb 6 4 kg Electrical specifications MTBF rating 288 615 hours 25 C Input power 80 W maximum Operating temperature 0 to 40 C Storage temperature 40 to 70 C Maintenance port 8 pin mini DIN Table 79 Maintenance port pin assignments for 8661 SAM Connector Pin number Signal 3 SAM TxD to host RxD 4 Serial ground 5 Host TxD to SAM RxD 1 2 6 7 8 Not used Nortel Ethernet ...

Страница 139: ...ted Cable specifications Category 3 4 or 5 UTP cable 10 Mbps operation Category 5 UTP cable 100 Mbps operation 10 100BASE T Maximum distance 328 ft 100 m 1000BASE SX 62 5 µm multimode fiber optic cable 722 ft 220 m 160 MHz km bandwidth 902 ft 275 m 200 MHz km bandwidth 50 µm multimode fiber optic cable 1604 ft 500 m 400 MHz km bandwidth 1804 ft 550 m 400 MHz km bandwidth Optical specifications Wav...

Страница 140: ...mit data TX 4 5 7 8 Not used Table 82 Maintenance port pin assignments for WSM Connector Pin number Signal 3 WSM TxD to host RxD 4 Serial ground 5 Host TxD to WSM RxD 1 2 6 7 8 Not used 8691 SF CPU module The following table describes the 8691 SF CPU module specifications Table 83 8691 SF CPU module specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Nortel Ethernet R...

Страница 141: ...ications Ethernet Management port Category 3 4 or 5 UTP cable 10 Mbps operation Category 5 UTP cable 100 Mbps operation Console port RS 232 cable Modem port DTE to DCE cable straight or transmit cable The following table provides power specifications for the 8691 SF CPU module Table 84 8691 SF CPU power specifications Specification Without Mezz With Mezz 3 3 V power W 43 9 59 4 12 V power W 48 0 5...

Страница 142: ...nals and GND is sufficient for the console serial port to fully function The Console port does not support inbound flow control that is the port does not toggle control lines to indicate an input buffer full condition The following table lists the pin assignments for the Console port for both the DTE and DCE settings Table 86 Pin assignments 8691 SF CPU module Console port Switch position Connecto...

Страница 143: ...ule The following table describes the 8692 SF CPU specifications Table 88 8692 SF CPU specifications Physical specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 7 2 lb 3 3 kg Electrical specifications Input power 100 6 W 142 5 W with SuperMezz maximum See the following table Thermal rating 343 0 485 9 Btu hr maximum MTBF rating 213 454 hr Connector types Etherne...

Страница 144: ...ule Table 89 8692 SF CPU power specifications Specification Without SuperMezz With SuperMezz 3 3 V power W 50 2 82 5 12 V power W 50 4 60 0 Total power W 100 6 142 5 8692 SF CPU Management port The Management port is a 10 100 Mbps Ethernet port implemented on an RJ 45 connector wired as an MDI connection The following table shows the pin assignments for this connector Table 90 Pin assignments 8692...

Страница 145: ... for the Console port for both the DTE and DCE settings Table 91 Pin assignments 8692 SF CPU module Console port Switch position Connector Pin number DCE left DTE right 2 TXD Output RXD Input 3 RXD Input TXD Output 4 DSR Input DTR Output 5 GND GND 6 DTR Output DSR Input 7 CTS Input RTS Output 8 RTS Output CTS Input 8692 SF CPU modem port The Modem serial port is implemented on a DB 9 connector wir...

Страница 146: ...Routing Switch 8600 modules Maximum number of ports for each chassis Module type Port type 8003 8006 8010 and 8010co E and M modules 1000BASE SX 16 32 64 1000BASE LX 16 32 64 1000BASE ZX 16 32 64 1000BASE XD 16 32 64 1000BASE CW DM 16 32 64 8608GBE and 8608GBM 1000BASE T 16 32 64 8608GTE and 8608GTM 1000BASE T 16 32 64 8608SXE 1000BASE SX 16 32 64 8616GTE 1000BASE T 32 64 128 8616SXE 1000BASE SX 3...

Страница 147: ... 16 32 48 OC 12c MDA 4 8 12 8672ATME and 8672ATMM DS 3 MDA 8 16 24 OC 3c MDA 12 24 24 8683POSM OC 12c MDA 6 12 12 R series modules 10GBASE SR Not supported 48 96 10GBASE LR L W Not supported 48 96 10GBASE LRM Not supported 48 96 10GBASE ER EW Not supported 48 96 8612XLRS 10GBASE ZR ZW Not supported 48 96 1000BASE SX Not supported 120 240 1000BASE LX Not supported 120 240 1000BASE ZX Not supported ...

Страница 148: ... supported 8 16 10GBASE LR L W Not supported 8 16 10GBASE LRM Not supported 8 18 10GBASE ER EW Not supported 8 16 10GBASE ZR ZW Not supported 8 16 8634XGRS 10GBASE LRM Not supported 8 16 1000BASE SX Not supported 192 384 1000BASE LX Not supported 192 384 1000BASE ZX Not supported 192 384 1000BASE XD Not supported 192 384 1000BASE CW DM Not supported 192 384 8648GBRS 1000BASE T Not supported 192 38...

Страница 149: ... supported 12 24 10GBASE LRM Not supported 12 24 10GBASE ER EW Not supported 12 24 8683XZR 10GBASE ZR ZW1 Not supported 4 with standard fan tray 12 with high speed cooling module 8 with standard fan tray 24 with high speed cooling module 1Nortel recommends that you install only one 10GBASE ZR ZW XFP in one 8683XLR module due to cooling limitations on the 8683XLR and XZR when using standard fan tra...

Страница 150: ...150 Technical specifications Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 151: ...ution statement CAUTION Risk of electromagnetic interference This device is a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users are required to take appropriate measures necessary to correct the interference at their own expense CAUTION ATTENTION Le périphérique est un produit de Classe A Le fonctionnement de cet équipemen...

Страница 152: ...os tomem as medidas necessárias para corrigir a interferência por sua própria conta CAUTION ATTENZIONE Questo dispositivo è un prodotto di Classe A Il funzionamento di questo apparecchio in aree residenziali potrebbe causare interferenze dannose nel cui caso agli utenti verrà richiesto di adottare tutte le misure necessarie per porre rimedio alle interferenze a proprie spese Electromagnetic interf...

Страница 153: ... müssen ohne ein Ersatzmodul zur Hand zu haben lassen Sie das defekte Modul installiert oder installieren Sie eine Aussparungsabdeckung Wird das Vermittlungssystem mit einem unbestückten Modulsteckplatz betrieben kann dies elektromagnetische Störungen verursachen die sich auch auf andere Geräte in der Umgebung auswirken Außerdem kann eine unzureichende Gerätekühlung die Folge sein CAUTION PRECAUCI...

Страница 154: ...stallare un pannello di riempimento L uso dell interruttore con l alloggiamento modulo vuoto può provocare un interferenza elettromagnetica su altri apparecchi presenti nella zona oltre che un inadeguato raffreddamento dell apparecchio stesso Electrostatic discharge caution statement CAUTION ESD To prevent damage from electrostatic discharge always wear an antistatic wrist strap connected to an el...

Страница 155: ...seira antiestática que esteja conectada a uma tomada de descarga eletrostática ESD quando estiver realizando a manutenção deste produto Certifique se de que a pulseira esteja em contato com sua pele CAUTION ATTENZIONE ESD Per evitare danni derivanti da scariche elettrostatiche indossare sempre un polsino antistatico collegato a una presa di scarico elettrostatico ESD durante la manutenzione del pr...

Страница 156: ...ERTENCIA Riesgo de lesión en los ojos por láser El equipo de fibra óptica puede emitir una luz láser o infrarroja que dañe sus ojos Nunca mire un puerto de fibra óptica o conector Siempre asuma que los cables de fibra óptica están conectados a una fuente de luz WARNING AVISO O laser pode causar ferimentos no olho O equipamento de fibra ótica pode emitir laser ou luz infravermelha que pode causar d...

Страница 157: ...ment 157 ottica Tenere sempre presente che i cavi a fibra ottica sono collegati a una sorgente luminosa Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 158: ...158 Translations of Safety Messages Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 159: ... 49 technical specifications 130 8632TXE module description 41 status LEDs 42 technical specifications 124 8632TXM module description 41 status LEDs 42 8634XGRS module 58 status LEDs 59 8648GBRS module 61 status LEDs 62 8648GTR module description 50 status LEDs 51 63 technical specifications 132 8648TXE module description 43 status LEDs 44 technical specifications 125 8648TXM module description 43...

Страница 160: ...DB 9 142 145 RJ 45 134 142 144 Console port 71 77 142 145 CPU expansion card installing 100 CPU subsystem 67 CRUs customer replaceable units 8608SXE module description 35 8616SXE module description 38 8624FXE module description 39 8648GTR module description 50 8691 SF CPU module description 67 8692 SF CPU module description 72 D DTE DCE switch 142 145 description 71 77 E environmental specificatio...

Страница 161: ...MM module 127 8683POSM module 129 P PCMCIA card slot 72 77 pin assignments 10 100 1000 Mbps ports 134 Console port 142 145 Ethernet Management port 142 144 modem port 143 145 ports 10 100 1000 Mbps 134 100BASE FX 39 Console 142 145 Ethernet Management 71 76 142 144 modem 143 145 serial 71 77 POSM module 46 R redundancy CPUs 68 73 reset button 71 77 routing switch fabric module description 68 S saf...

Страница 162: ...162 W WSM module technical specifications 139 X XFPs Nortel qualified 66 Nortel Ethernet Routing Switch 8600 Installation Modules NN46205 304 02 02 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Страница 163: ......

Страница 164: ...greed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks Velcro is a trademark of Velcro Industries B V PowerPC is a trademark of International Business ...

Отзывы: