Configuring the Carrier Remote IPE
117
Table 17
To change the system configuration record (LD 17) (cont’d.)
Prompt
Response
Description
CEQU
YES
Change equipment
MPED
8D
Peripheral density
Table 18
To configure the Remote Carrier IPE site (LD 97)
REQ
CHG
Remote Carrier Interface definition
TYPE
XPE
Remote Peripheral Controller (RCI) ID
SUPL
0-252
Prints superloop type and number
XPEC
2
Controller ID number.
LOC
SCLARA
remote site location example. Use any six
alphanumeric characters to identify the remote
site.
RGTP
(8) 16
Number of concurrent ringers. Change to 16
unless ringing generator is an older type.
After defining the new Peripheral Controller (RCI), define the superloop
for the Local Carrier Interface card.
Table 19
To define a carrier superloop
Prompt
Response
Description
REQ
CHG
Adding a new Local Carrier Interface card
TYPE
SUPL
Adding a superloop for the Local Carrier
Interface card.
SUPL
0–252
Superloop number
SLOT
(L) R
Superloop card side for the Local Carrier
Interface card, where L (left) is default position.
SUPT
CARR
Carrier superloop type. Prompted when
REM_IPE 286 software package is installed.
XPEC
1–99
Remote Carrier Interface card (Controller ID
number) previously equipped. Defaults to shelf
0 segment 0-3 for
SUPT = CARR
To configure the Carrier Remote IPE superloop and the Carrier Remote
IPE column or cabinet site, load Configuration Record Program LD 17 and
Configuration Record Program LD 97.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.