102
Equipment installation and configuration
13
Disconnect the power cord from the wall outlet for the AC system
or the DC power source for the DC system and reconnect the 6
AWG ground wire to the cabinet ground lug.
14
Reconnect the NTAK98AA supply power cord to the AC power
outlet for an AC system or to the DC source for a DC system.
15
If the Carrier Remote IPE requires an expansion cabinet to
accommodate up to 16 IPE cards, repeat steps 1 through 14 for
the NTBK70 expansion cabinet.
16
Connect the NT1P70/NT1P60 main cabinet to the NTBK70
expansion cabinet by installing the cable between connector P1
of the main cabinet and P1 of the expansion cabinet. Install the
cabinets side-by-side or above each other keeping in mind that
the inter-cabinet cable is 7 ft (21 m) long.
17
Install the adhesive label strip to the expansion cabinet
designating the card slots from 10 to 15.
--End--
This completes the cabinet installation and system ground test.
Removing the fiber I/O bracket assembly
The NT1P70/NT1P60 main Carrier Remote IPE cabinet is equipped with
a I/O bracket assembly used in Fiber Remote IPE. This bracket must be
removed and the NT7R94AA Remote Cabinet Cable Assembly must be
installed in its place. Refer to
Figure 17 "Carrier cable routing for the
Carrier Remote IPE cabinet" (page 104)
.
To remove this bracket, follow the steps in
fiber I/O bracket assembly” (page 102)
Procedure 20
Removing the fiber I/O bracket assembly
Step
Action
1
Unscrew the retaining screw holding the bracket in place.
The screw is located at the upper front of the bracket.
2
Remove the retaining screw and swing the front of the bracket to
the left by 45 degrees.
3
Slide the entire bracket forward to clear the hinge tabs at the rear
of the bracket.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.